Paper · MFC
Influence of nitrogen limitation on performance of a microbial fuel cell
Summary
What the paper reports, in its own words.
Abstract
We describe the operation of a microbial fuel cell (MFC) system operating on a synthetic wastewater (acetic acid), under conditions of increasing nitrogen limitation. Two MFCs were operated under feed conditions which spanned a range of TKN/COD values of 1.6–28 mg/g. Stable operation was observed in all cases, even when no ammoniacal nitrogen was added to the cell. Improved electrochemical performance (measured as power density, W/m2) was observed as nitrogen limitation was imposed on the cells. Even with no ammonium addition, continuous function of the cell was maintained, at levels consistent with operation at balanced nutrient supplementation. The work has implicated biological nitrogen fixation as a potential source of nitrogen within the MFC. Whilst this hypothesis has yet to be confirmed, the work highlights the opportunity for continuous operation of microbial fuel cells utilising wastewaters with extremely low nitrogen levels, present in pulp and paper, pharmaceutical and petrochemical industries. Further, the described increases in some of the electrochemical indices (e.g. power density) under application of nitrogen limitation may provide a new approach to increasing fuel cell performance. Finally, the lack of any need to add supplemental nitrogen to a MFC-based wastewater treatment technology holds potential for significant financial and environmental savings.
AI summary: matches the abstract (70% confidence) · review against source PDF
Extracted values
Every value pulled from the paper, with its source, so each number can be checked against the text.
n = 1 extracted value
Select a citation to see the quote, page and confidence behind a value.
| Parameter | Value | Unit | Confidence | Source |
|---|---|---|---|---|
| Substrate | wastewater | — | 80% | llm |
Methodology
What was the system and how was it run
Methodology
Methodology
Two MFCs were operated under feed conditions spanning a range of TKN/COD values of 1.6–28 mg/g.
System configuration
| Field | Value |
|---|---|
| system type | MFC |
Performance metrics
| Field | Value |
|---|---|
| citation count | 10 |
Operational parameters
| Field | Value |
|---|---|
| substrate | ["wastewater"] |
Pipeline
Raw extractions, artifacts, quality signal
Extraction quality
honesty signalCalibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.
Parameter completeness
25%
Fraction of expected parameters extracted
Data completeness
50%
Overall extraction coverage across fields
AI confidence
70%
Model self-reported confidence
Mean parameter confidence
80%
Average confidence across PaperParameter rows surfaced above
review against source PDF before citing · scores 0–1
Chart explorer
Move the inputs this paper used and see how the predicted outcome shifts.
Explore model
The reactor in 3D, with flow you can switch on and off.
AI insights
Contradictions, gaps and opportunities found by comparing this paper with the corpus.
Compare similar papers
The nearest papers by system, materials and organisms, with their outcomes side by side.
Representative model, generic MFC
Tap to interactRepresentative model, generic MFC
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
Keywords
- Microbial fuel cell
- Kjeldahl method
- Nitrogen
- Effluent
- Wastewater
- Pulp and paper industry
Cite
P. Belleville, P. J. Strong, P. H. Dare et al. (2011). Influence of nitrogen limitation on performance of a microbial fuel cell. Water Science and Technology. https://doi.org/10.2166/wst.2011.111
- Journal
- Water Science and Technology