Paper · MFC
Membrane filtration biocathode microbial fuel cell for nitrogen removal and electricity generation
Summary
What the paper reports, in its own words.
Abstract
Conductive materials with attached biofilms, were used as membrane filtration biocathodes to filter the effluent and supply electrons for denitrification. Stainless steel mesh and carbon felt were employed to fabricate membrane modules, and the two MFC systems were termed as M1 and M2, respectively. High effluent quality was obtained with M1 and M2 in terms of turbidity, COD and ammonium. In M1, no bioelectrochemical denitrification took place, while nitrate decreased from 35.88±4.15 to 27.33±5.32mg-N/L through the membrane in M2, causing a removal efficiency of 23.3±6.5% with respect to cathodic nitrate. The denitrification ceased without electricity. The maximum power densities of M1 and M2 were 121 and 1253mW/m³, respectively. Micrococcus bacteria and rod-shaped bacteria covered the surface of carbon felt and fewer bacteria were found on stainless steel mesh. According to fluorescence in situ hybridization, the putative bacteria affiliated with Paracoccus genus and Pseudomonas spp. dominated in the interior biofilm on carbon felt for denitrification. Results demonstrate that the carbon felt system can perform bioelectrochemical denitrification to polish the effluent.
Extracted values
Every value pulled from the paper, with its source, so each number can be checked against the text.
n = 3 extracted values
Select a citation to see the quote, page and confidence behind a value.
0 of 3 extracted rows modelable
- 3 no SI value
| Parameter | Value | Unit | Confidence | Source | Modelable |
|---|---|---|---|---|---|
| Cathode material | biocathode | — | 60% | extracted | Excluded: no SI value |
| Cathode material | carbon felt and stainless steel mesh | — | 50% | extracted | Excluded: no SI value |
| Membrane material | membrane filtration biocathode | — | 50% | extracted | Excluded: no SI value |
Pipeline
Raw extractions, artifacts, quality signal
Extraction quality
honesty signalCalibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.
Parameter completeness
25%
Fraction of expected parameters extracted
Data completeness
40%
Overall extraction coverage across fields
AI confidence
70%
Model self-reported confidence
Mean parameter confidence
53%
Average confidence across PaperParameter rows surfaced above
review against source PDF before citing · scores 0–1
Chart explorer
Move the inputs this paper used and see how the predicted outcome shifts.
Explore model
The reactor in 3D, with flow you can switch on and off.
AI insights
Contradictions, gaps and opportunities found by comparing this paper with the corpus.
Compare similar papers
The nearest papers by system, materials and organisms, with their outcomes side by side.
Representative model, generic MFC
Tap to interactRepresentative model, generic MFC
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
Keywords
- Denitrification
- Effluent
- Microbial fuel cell
- Nitrate
- Filtration (mathematics)
- Carbon fibers
Cite
Guangyi Zhang, Hanmin Zhang, Yanjie Ma et al. (2014). Membrane filtration biocathode microbial fuel cell for nitrogen removal and electricity generation. Enzyme and Microbial Technology. https://doi.org/10.1016/j.enzmictec.2014.04.005
- PubMed
- 24835100
Open in lab for full controls, parameter editing, and template overlays.
Open in lab