Enhanced nitrogen removal of low C/N wastewater using a novel microbial fuel cell (MFC) with Cupriavidus sp. S1 as a biocathode catalyst (BCS1)

01

Summary

What the paper reports, in its own words.

3D Interactive ModelAI Enhanced· 70%

Abstract

AbstractBACKGROUNDAn innovative microbial fuel cell (MFC) using Cupriavidus sp. S1 as the biocathode catalyst was developed to improve nitrogen removal from low carbon/nitrogen (C/N) wastewater.RESULTSThe desirable external resistance was 100 Ω in this study, with an optimal total nitrogen (TN) removal efficiency of 95.71%, and a maximum current density and power density of 7583.89 ± 318.11 mA m⁻³ and 932 mW m⁻³ at C/N = 2, respectively, which initially confirmed the ability of Cupriavidus sp. S1 to obtain electrons from the electrode. The maximum tolerance of the system at Rext of 100 Ω was C/N = 1, with a TN removal efficiency of 90.87%. Compared with the open circuit, the TN removal increased by approximately 21.60% and 52.02% at C/N = 2 and 1, respectively, which expanded the application area for the dominant denitrifying bacteria S1. Additionally, the system exhibits the obvious merits of less sludge production, low energy consumption and the recovery of some energy.CONCLUSIONBased on these results, domesticated Cupriavidus sp. S1 possesses electrochemical activity. Thus, the system has great potential for efficient and cost‐effective nitrogen removal from nitrate‐containing low C/N wastewater and energy recovery. © 2019 Society of Chemical Industry

AI summary: matches the abstract (70% confidence) · review against source PDF

Key findings

  • 71%, and a maximum current density and power density of 7583.
  • 11 mA m⁻³ and 932 mW m⁻³ at C/N = 2, respectively, which initially confirmed the ability of Cupriavidus sp.
  • 87%.
  • Compared with the open circuit, the TN removal increased by approximately 21.
02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 8 extracted values

Select a citation to see the quote, page and confidence behind a value.

0 of 6 extracted rows modelable

  • 2 not canonicalised (no canonical slug)
  • 4 no SI value
ParameterValueUnitConfidenceSourceModelable
Substratewastewater—80%
llm
Coulombic efficiency95.7%80%
llm
Catalyst(bcs1)—60%
extracted
Excluded: not canonicalised (no canonical slug)
Cathode materialbiocathode—60%
extracted
Excluded: no SI value
Cathode materialCupriavidus sp. S1—50%
extracted
Excluded: no SI value
Maximum Current Density7,580mA/m²50%
extracted
Excluded: no SI value
Maximum power density0.932mW/m²50%
extracted
Excluded: no SI value
Internal resistance100Ω50%
extracted
Excluded: not canonicalised (no canonical slug)

Literature priors

Distribution

Against the literature

The author’s reported value (▼) sits on top of the literature distribution from MESS-Parameters. Values outside the band are flagged as outliers.

Coulombic efficiency95.71percent

Methodology

What was the system and how was it run

Methodology

Methodology

A novel microbial fuel cell (MFC) was developed using Cupriavidus sp. S1 as the biocathode catalyst to enhance nitrogen removal from low C/N wastewater.

System configuration

FieldValue
system typeMFC

Performance metrics

FieldValue
coulombic efficiency95.71
citation count17

Operational parameters

FieldValue
substrate["wastewater"]

Outcomes

What was measured and what worked

Key takeaways

Coulombic efficiency

electrochemistry

95.71percent

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

50%

Fraction of expected parameters extracted

Data completeness

70%

Overall extraction coverage across fields

AI confidence

70%

Model self-reported confidence

Mean parameter confidence

60%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

loading 3D model…

Representative model, generic MFC

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

MFC
System
0.93milliwatts per square metre
Best result · Power density
8
Extracted values
2020
Year

In this record

Organisms, parameters and materials this paper reports. Each links to its page.

Parameters · 1

Keywords

  • Microbial fuel cell
  • Denitrifying bacteria
  • Nitrogen
  • Wastewater
  • Nitrate