Research

Paper

Microbiome Composition and Dynamics of a Reductive/Oxidative Bioelectrochemical System for Perchloroethylene Removal: Effect of the Feeding Composition

01

Summary

What the paper reports, in its own words.

AI Enhanced· 82%

Abstract

Chlorinated solvents still represent an environmental concern that requires sustainable and innovative bioremediation strategies. This study describes the microbiome composition of a novel bioelectrochemical system (BES) based on sequential reductive/oxidative dechlorination for complete perchloroethylene (PCE) removal occurring in two separate but sequential chambers. The BES has been tested under various feeding compositions [i.e., anaerobic mineral medium (MM), synthetic groundwater (SG), and real groundwater (RG)] differing in presence of sulfate, nitrate, and iron (III). In addition, the main biomarkers of the dechlorination process have been monitored in the system under various conditions. Among them, Dehalococcoides mccartyi 16S rRNA and reductive dehalogenase genes ( tceA , bvcA , and vcrA ) involved in anaerobic dechlorination have been quantified. The etnE and etnC genes involved in aerobic dechlorination have also been quantified. The feeding composition affected the microbiome, in particular when the BES was fed with RG. Sulfuricurvum , enriched in the reductive compartment, operated with MM and SG, suggesting complex interactions in the sulfur cycle mostly including sulfur oxidation occurring at the anodic counter electrode (MM) or coupled to nitrate reduction (SG). Moreover, the known Mycobacterium responsible for natural attenuation of VC by aerobic degradation was found abundant in the oxidative compartment fed with RG, which was in line with the high VC removal observed (92 ± 2%). D. mccartyi was observed in all the tested conditions ranging from 8.78E + 06 (with RG) to 2.35E + 07 (with MM) 16S rRNA gene copies/L. tceA was found as the most abundant reductive dehalogenase gene in all the conditions explored (up to 2.46 E + 07 gene copies/L in MM). The microbiome dynamics and the occurrence of biomarkers of dechlorination, along with the kinetic performance of the system under various feeding conditions, suggested promising implications for the scale-up of the BES, which couples reductive with oxidative dechlorination to ensure the complete removal of highly chlorinated ethylene and mobile low-chlorinated by-products.

AI summary

82% confidence

This paper describes a sequential reductive/oxidative bioelectrochemical system (BES) for PCE dechlorination across two separate chambers, operated under three feeding regimes (mineral medium, synthetic groundwater, real groundwater). The reductive cathode achieved 95–97% PCE removal at rates of 99 µeq/Ld (MM) to 0.51 µeq/Ld (RG), while the oxidative anode removed >90% of VC and cis-DCE. Microbiome composition shifted dramatically with feeding: MM favored Sulfuricurvum (54.6%), SG enriched it further (93.1%), and RG diversified the community with Methylocystis and Mycobacterium. D. mccartyi abundance ranged 8.78E+06–2.35E+07 copies/L, with tceA as the dominant reductive dehalogenase gene (up to 2.46E+07 copies/L in MM). etnC and etnE genes for VC oxidation increased 100-fold under RG (2.36E+08 and 2.38E+08 copies/L respectively).

Key insights

  • Trade-off Cathode potential shift from −550 mV to −450 mV vs. SHE reduced RD rate from 99 to 68 µeq/Ld (31% decrease) when switching from MM to SG, indicating potential-dependent competition with sulfate reduction (3.2 meq/Ld).

    So what. Operators must account for competing electron sinks (sulfate, nitrate, iron) when setting cathode potential; lower potentials may suppress dechlorination in sulfate-rich groundwater.

  • Mechanism Real groundwater feeding caused a 100-fold increase in etnC and etnE genes (2.24E+06 to 2.36E+08 copies/L etnC; 6.86E+06 to 2.38E+08 copies/L etnE) despite lower chlorinated ethylene concentrations (0.2 µM PCE vs. 100 µM in MM), suggesting iron(III) reduction (945 meq/Ld) or natural organic matter drives ethenotroph enrichment.

    So what. In aged, iron-rich contaminated sites, expect strong ethenotroph populations even at low contaminant levels; design oxidative chambers to exploit this for polishing.

  • Performance Shorter HRT (1.8 days for RG vs. 5.1 days for MM) combined with galvanostatic control (+15 mA) in the oxidative reactor achieved 92% VC removal under RG, matching the +1.4 V potentiostatic control in MM, indicating current density may be a more robust operating parameter than potential in complex matrices.

    So what. For field deployment in variable groundwater, use galvanostatic control and shorter HRT to maintain VC removal despite compositional changes.

  • Threshold tceA gene copies dropped 132-fold from MM (2.46E+07) to SG (1.87E+05) despite similar PCE removal efficiency (97% vs. 95%), while vcrA and bvcA remained relatively stable, indicating tceA expression is suppressed by nitrate/sulfate availability even when dechlorination proceeds.

    So what. Do not use tceA gene abundance alone as a performance indicator in nitrate-containing groundwater; couple with functional assays or product quantification.

  • Mechanism Mycobacterium (ethenotroph) abundance in the oxidative reactor was 1.3% under MM but enriched to 1.4% under RG, correlating with 92% VC removal in both cases, suggesting VC removal is not limited by ethenotroph abundance but by cathode-supplied substrate or anode potential.

    So what. Ensure adequate VC supply from the reductive chamber and maintain anode potential/current; microbial community composition alone does not predict oxidative performance.

Contradictions1

Tensions the paper itself points to. Each side quotes the passage it comes from.

  • Within the paper tceA gene abundance does not correlate with PCE removal efficiency across feeding regimes

    One side

    MM: tceA 2.46E+07 copies/L, PCE removal 97%

    “tceA was found as the most abundant reductive dehalogenase gene in all the conditions explored (up to 2.46 E + 07 gene copies/L in MM)”
    Other side

    SG: tceA 1.87E+05 copies/L (132-fold lower), PCE removal 95% (only 2% lower)

    “the utilization of RG in the reactor yielded a low RD rate (0.51 ± 0.04 µeq/Ld) mostly due to the complexity of RG in terms of chemical composition”

    Authors’ reading. Authors attribute the tceA suppression in SG to competition from sulfate/nitrate reduction (3.2 meq/Ld sulfate reduction vs. 0.3 meq/Ld nitrate reduction), which diverts electrons away from dechlorination but does not prevent it. The system maintains high PCE removal because the cathode potential (−450 mV vs. SHE) still drives dechlorination, albeit at a lower rate (68 vs. 99 µeq/Ld). This is not a true contradiction but a trade-off: competing reactions suppress tceA expression without eliminating dechlorination.

Opportunity areas6

Specific gaps in this paper, with an experiment that would close each.

  • High No systematic variation of cathode potential between −550 and −450 mV vs. SHE in the presence of nitrate/sulfate to identify the threshold potential at which dechlorination is outcompeted by sulfate/nitrate reduction

    RD rate dropped 31% (99 to 68 µeq/Ld) when potential shifted from −550 to −450 mV and sulfate/nitrate were introduced, but the paper does not isolate the effect of potential alone. A potential sweep under constant SG composition would reveal the operating window.

    Try. Vary cathode potential from −600 to −350 mV vs. SHE in SG (30 mg NO3−/L, 200 mg SO42−/L); measure RD rate, sulfate reduction rate, nitrate reduction rate, and tceA abundance at each potential.

  • High No measurement of N2O or nitrite accumulation during nitrate reduction in the SG feeding condition

    Nitrate reduction was quantified at 0.3 meq/Ld in SG, but no speciation of products (NO2−, N2O, N2) was reported. Incomplete denitrification could produce N2O, a potent greenhouse gas, or accumulate toxic NO2−.

    Try. Measure NO3−, NO2−, N2O, and N2 in the reductive reactor outlet during SG feeding using ion chromatography and gas chromatography; vary cathode potential and HRT to optimize complete denitrification to N2.

  • Medium No direct measurement of cathode potential or current density in the reductive reactor during RG feeding; only applied potential (−450 mV vs. SHE) is reported

    RG contains 31 mg/L Fe total and 20 mg/L Fe3+, which may form a biofilm or precipitate on the electrode, changing the actual potential experienced by the biofilm. Iron(III) reduction dominated (945 meq/Ld), suggesting the electrode surface chemistry differs from MM/SG conditions.

    Try. Measure electrode impedance and surface potential using electrochemical impedance spectroscopy (EIS) during RG feeding; correlate with biofilm composition and iron(III) reduction rate.

  • Medium No variation of HRT in the oxidative reactor to determine the minimum residence time for VC removal under different feeding regimes

    HRT was 5.1 d (MM), 3.7 d (SG), and 1.8 d (RG), but these were not systematically varied. The 1.8 d HRT in RG achieved 92% VC removal, suggesting further reduction may be possible, which would improve throughput.

    Try. Reduce HRT from 1.8 to 0.9 d in RG feeding while maintaining galvanostatic control at +15 mA; measure VC and cis-DCE removal efficiency and etnC/etnE gene abundance.

  • Medium No measurement of dissolved oxygen (DO) in the oxidative reactor outlet or control of aeration to optimize ethenotroph activity

    etnC and etnE genes encode aerobic VC oxidation enzymes, but the paper does not report DO levels or aeration strategy. RG feeding achieved 100-fold higher etnC/etnE abundance, possibly due to higher DO from natural organic matter oxidation or electrode-driven oxygen production.

    Try. Measure DO in the oxidative reactor outlet under MM, SG, and RG feeding; vary aeration rate (0–5 L/min) and measure VC removal efficiency and etnC/etnE abundance.

  • Low No measurement of catholyte pH in the reductive reactor, which affects electrode potential and microbial metabolism

    pH is critical for electrode kinetics and denitrification (optimal pH 6.5–8.5), but only the applied potential is reported. MM contains 2.5 g/L NaHCO3 (buffering), while SG and RG may have different pH profiles.

    Try. Monitor pH in the reductive reactor outlet during MM, SG, and RG feeding; correlate with RD rate, sulfate reduction rate, and D. mccartyi abundance.

Generated by MESSAI extraction pipeline · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 53 extracted values

Select a citation to see the quote, page and confidence behind a value.

12 of 53 extracted rows modelable

  • 32 not canonicalised (no canonical slug)
  • 9 no SI value
ParameterValueUnitConfidenceSourceNotesModelable
PCE removal efficiency95 ± 6 (SD)%95%
gas chromatography with fid
"In the reductive compartment, high PCE removal efficiencies corresponded to 97 ±…" · substrate=perchloroethylene (PCE), steady_stateExcluded: not canonicalised (no canonical slug)
PCE removal efficiency×297 ± 1 (SD)%95%
gas chromatography with fid
"In the reductive compartment, high PCE removal efficiencies corresponded to 97 ±…" · substrate=perchloroethylene (PCE), steady_stateExcluded: not canonicalised (no canonical slug)
Dehalococcoides mccartyi 16S rRNA2.35E7gene copies/L95%
droplet digital pcr (ddpcr)
"Initially, by MM feeding, D. mccartyi 16S rRNA accounted for 2.35E + 07 gene cop…" · substrate=perchloroethylene (PCE), steady_stateExcluded: not canonicalised (no canonical slug)
Dehalococcoides mccartyi 16S rRNA1.78E7gene copies/L95%
droplet digital pcr (ddpcr)
"a similar abundance was observed during the operation with SG (1.78E + 07 gene c…" · substrate=perchloroethylene (PCE), steady_stateExcluded: not canonicalised (no canonical slug)
Dehalococcoides mccartyi 16S rRNA8.78E6gene copies/L95%
droplet digital pcr (ddpcr)
"but decreased by one order of magnitude under RG feeding (8.78E + 06 gene copies…" · substrate=real groundwater, steady_stateExcluded: not canonicalised (no canonical slug)
tceA gene copies2.46E7gene copies/L95%
droplet digital pcr (ddpcr)
"tceA was found as the most abundant reductive dehalogenase gene in all the condi…" · substrate=perchloroethylene (PCE), steady_stateExcluded: not canonicalised (no canonical slug)
tceA gene copies187,000gene copies/L95%
droplet digital pcr (ddpcr)
"tceA 1,87E+05" · substrate=perchloroethylene (PCE), steady_stateExcluded: not canonicalised (no canonical slug)
tceA gene copies6.03E6gene copies/L95%
droplet digital pcr (ddpcr)
"tceA 6,03E+06" · substrate=real groundwater, steady_stateExcluded: not canonicalised (no canonical slug)
vcrA gene copies31,400gene copies/L95%
droplet digital pcr (ddpcr)
"vcrA 3,14E+04" · substrate=perchloroethylene (PCE), steady_stateExcluded: not canonicalised (no canonical slug)
vcrA gene copies149,000gene copies/L95%
droplet digital pcr (ddpcr)
"vcrA 1,49E+05" · substrate=perchloroethylene (PCE), steady_stateExcluded: not canonicalised (no canonical slug)
vcrA gene copies23,900gene copies/L95%
droplet digital pcr (ddpcr)
"vcrA 2,39E+04" · substrate=real groundwater, steady_stateExcluded: not canonicalised (no canonical slug)
bvcA gene copies27,900gene copies/L95%
droplet digital pcr (ddpcr)
"bvcA 2,79E+04" · substrate=perchloroethylene (PCE), steady_stateExcluded: not canonicalised (no canonical slug)
bvcA gene copies83,500gene copies/L95%
droplet digital pcr (ddpcr)
"bvcA 8,35 E + 04" · substrate=perchloroethylene (PCE), steady_stateExcluded: not canonicalised (no canonical slug)
bvcA gene copies35,600gene copies/L95%
droplet digital pcr (ddpcr)
"bvcA 3,56E+04" · substrate=real groundwater, steady_stateExcluded: not canonicalised (no canonical slug)
etnC gene copies2.24E6gene copies/L95%
droplet digital pcr (ddpcr)
"EtnC 2,24E+06" · substrate=vinyl chloride (VC), steady_stateExcluded: not canonicalised (no canonical slug)
etnC gene copies2.59E6gene copies/L95%
droplet digital pcr (ddpcr)
"EtnC 2,59E+06" · substrate=cis-dichloroethylene (cis-DCE), steady_stateExcluded: not canonicalised (no canonical slug)
etnC gene copies2.36E8gene copies/L95%
droplet digital pcr (ddpcr)
"EtnC 2,36E+08" · substrate=real groundwater, steady_stateExcluded: not canonicalised (no canonical slug)
etnE gene copies6.86E6gene copies/L95%
droplet digital pcr (ddpcr)
"EtnE 6,86E+06" · substrate=vinyl chloride (VC), steady_stateExcluded: not canonicalised (no canonical slug)
etnE gene copies4.24E6gene copies/L95%
droplet digital pcr (ddpcr)
"EtnE 4,24E+06" · substrate=cis-dichloroethylene (cis-DCE), steady_stateExcluded: not canonicalised (no canonical slug)
etnE gene copies2.38E8gene copies/L95%
droplet digital pcr (ddpcr)
"EtnE 2,38E+08" · substrate=real groundwater, steady_stateExcluded: not canonicalised (no canonical slug)
Hydraulic retention time1.8d90%
calculated from flow rate and reactor volume
"The reactor was fed with an average flow rate of 4.6 ± 0.5 L/d, which correspond…" · substrate=real groundwaterModelable
Hydraulic retention time5.1d90%
calculated from flow rate and reactor volume
"The average flow rate for the system was 1.62 ± 0.06 L/d that resulted in HRT of…" · substrate=perchloroethylene (PCE)Modelable
Hydraulic retention time3.7d90%
calculated from flow rate and reactor volume
"The average flow rate was 2.2 ± 0.7 L/d that led to a 3.7-day HRT." · substrate=perchloroethylene (PCE)Modelable
Operational Taxonomic Units2.44—90%
16s rrna gene amplicon sequencing, shannon index calculation
"The 16S rRNA gene amplicon sequencing performed on the outlet of the cathodic co…" · substrate=perchloroethylene (PCE), steady_stateModelable
Operational Taxonomic Units0.52—90%
16s rrna gene amplicon sequencing, shannon index calculation
"The 16S rRNA gene amplicon sequencing performed on the outlet of the cathodic co…" · substrate=perchloroethylene (PCE), steady_stateModelable
Showing 25 of 52

Methodology

What was the system and how was it run

Methodology

Methodology

The study employed a two-chamber sequential bioelectrochemical system with a graphite granule cathode (reductive) and mixed metal oxide anode (oxidative), operated under potentiostatic control (−550 to −450 mV vs. SHE for cathode; +1.4 V vs. SHE for anode) or galvanostatic control (+15 mA for oxidative in RG). Three feeding regimes were tested: mineral medium (MM, 100 µM PCE, HRT 5.1 d), synthetic groundwater (SG, 100 µM PCE in reductive, 20 µM cis-DCE in oxidative, HRT 3.7 d), and real groundwater (RG, 35 µg/L PCE, HRT 1.8 d). Microbiome composition was characterized by 16S rRNA gene amplicon sequencing (V1–V3 regions, MiSeq platform), and functional genes (D. mccartyi 16S rRNA, tceA, bvcA, vcrA, etnC, etnE) were quantified by droplet digital PCR (ddPCR) on samples collected at day 70 of each feeding condition. Chlorinated ethylenes, sulfate, nitrate, and Fe3+ were quantified by gas chromatography and ion chromatography.

System configuration

FieldValue
reactor typeBES
chamber config2-chamber

Performance metrics

FieldValue
citation count15

Operating conditions

11 runs extracted
RunT°CpHanpHcatSubstrate[S]mg/LHRThModeR_extΩV_appVInoculum
v2-2b83910b272b88e2———perchloroethylene (PCE)100———-0.55—
v2-2f3bd9357b981460———perchloroethylene (PCE)100—steady_state—-0.45—
v2-406ce0478c18283d———real groundwater————-0.45—
v2-787c33681ece064e———perchloroethylene (PCE)100———-0.45—
v2-7c32cf418e3318eb———perchloroethylene (PCE)100—steady_state—-0.55—
v2-b2ae41ad5e8121e9———real groundwater——————
v2-ce86bf4fcdd10524———cis-dichloroethylene (cis-DCE)20—steady_state—1.4—
v2-d9fa173510eb2b25———real groundwater——steady_state———
v2-e0047b47808ecc96———real groundwater——steady_state—-0.45—
v2-e2a113203fda4ebe———vinyl chloride (VC)——steady_state—1.4—
v2-eff9c490b5f435e7———perchloroethylene (PCE)——steady_state—-0.55—

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

13%

Fraction of expected parameters extracted

Data completeness

40%

Overall extraction coverage across fields

AI confidence

82%

Model self-reported confidence

Mean parameter confidence

92%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

07

Source PDF

The paper as published.

No 3D model is mapped to this paper yet. The values extracted from it are listed under Extracted values.

53
Extracted values
2022
Year

Keywords

  • Reductive dechlorination
  • Dehalogenase
  • Environmental chemistry
  • Sulfur
  • Bioremediation
  • Enrichment culture

Cite

M. L. Di Franca, B. Matturro, S. Crognale et al. (2022). Microbiome Composition and Dynamics of a Reductive/Oxidative Bioelectrochemical System for Perchloroethylene Removal: Effect of the Feeding Composition. Frontiers in Microbiology. https://doi.org/10.3389/fmicb.2022.951911