AI summary

82% confidence

This study presents an integrated vertical flow constructed wetland-microbial fuel cell (IVCW-MFC) system for simultaneous swine wastewater treatment and bioelectricity generation. The novel design combines downflow and upflow regions to create distinct aerobic, anoxic, and anaerobic zones, achieving 79.65% COD removal and 77.5% ammonia nitrogen removal with peak power output of 713 mV and 456 mW/m³. The activated carbon anode layer promoted electrochemically active bacteria (Geobacter and Desulfuromonas), enabling stable long-term operation under continuous flow conditions.

Generated by MESSAI extraction pipeline · review against source PDF

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

No values extracted from this paper yet.

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC

What worked

No outcome metrics extracted yet.

Abstract

A novel approach, combining a microbial fuel cell (MFC) with an integrated vertical flow constructed wetland (IVCW), was developed, and its ability to simultaneously produce electrical energy while treating swine wastewater was verified. The system combined the singular water flow path of a traditional vertical flow constructed wetland (upflow and downflow)-microbial fuel cell (CW-MFC), which demonstrates better characteristics in the aerobic, anoxic, and anaerobic regions. It not only enhanced the anti-pollution load ability and the organic compound removal effect, but also improved the gradient difference in the redox potential of the system. The results showed that the structure and substrate distribution in the device could both improve swine wastewater treatment and increase bioelectricity generation capabilities. The average chemical oxygen demand (COD) and ammonia nitrogen (NH 4 + -N) removal efficiencies were as high as 79.65% and 77.5%, respectively. Long-term and stable bioelectricity generation was achieved under continuous flow conditions. The peak values of the output voltage and power density were 713 mV and 456 mW m -3 . The activated carbon layer at the bottom of this system provided a larger surface for the growth of microbes. It showed significant promotion of the relative abundance of electrochemically active bacteria, which might result in the increase of bioelectricity generation in integrated vertical flow constructed wetland-microbial fuel cells (IVCW-MFCs). The electrochemically active bacteria, Geobacter and Desulfuromonas , were detected in the anodic biofilm by high-throughput sequencing analysis.

Keywords

AmmoniaWetlandMicrobial fuel cellOrganic matterProcess (computing)Constructed wetland

Identifiers

PubMed
35515927
Journal
RSC Advances
Year
2019