Research

Paper · MFC

Organic matter and ammonia removal by a novel integrated process of constructed wetland and microbial fuel cells

01

Summary

What the paper reports, in its own words.

3D Interactive ModelAI Enhanced· 72%

Abstract

A novel approach, combining a microbial fuel cell (MFC) with an integrated vertical flow constructed wetland (IVCW), was developed, and its ability to simultaneously produce electrical energy while treating swine wastewater was verified. The system combined the singular water flow path of a traditional vertical flow constructed wetland (upflow and downflow)-microbial fuel cell (CW-MFC), which demonstrates better characteristics in the aerobic, anoxic, and anaerobic regions. It not only enhanced the anti-pollution load ability and the organic compound removal effect, but also improved the gradient difference in the redox potential of the system. The results showed that the structure and substrate distribution in the device could both improve swine wastewater treatment and increase bioelectricity generation capabilities. The average chemical oxygen demand (COD) and ammonia nitrogen (NH 4 + -N) removal efficiencies were as high as 79.65% and 77.5%, respectively. Long-term and stable bioelectricity generation was achieved under continuous flow conditions. The peak values of the output voltage and power density were 713 mV and 456 mW m -3 . The activated carbon layer at the bottom of this system provided a larger surface for the growth of microbes. It showed significant promotion of the relative abundance of electrochemically active bacteria, which might result in the increase of bioelectricity generation in integrated vertical flow constructed wetland-microbial fuel cells (IVCW-MFCs). The electrochemically active bacteria, Geobacter and Desulfuromonas , were detected in the anodic biofilm by high-throughput sequencing analysis.

AI summary

72% confidence

This paper describes an integrated vertical-flow constructed wetland–microbial fuel cell (IVCW-MFC) treating swine wastewater with dual downflow–upflow zones. The closed-circuit system achieved 79.65% COD removal (102.7 mg/L effluent from 505 mg/L inlet) and 77.5% NH₄⁺–N removal (average inlet 215 mg/L) over 92 days at 2-day HRT, while generating 713 mV peak voltage and 456 mW/m³ power density. The anode region (10.4% of liquid volume) removed 58.93% of total COD and 71.4% of total NH₄⁺–N, with nitrification producing NO₃⁻–N that was subsequently denitrified to 75.13% removal. Closed-circuit operation improved COD removal by 14.94% over open-circuit, attributed to the anode acting as a temporary electron acceptor.

Key insights

  • Mechanism Anode region (10.4% of liquid volume) removed 58.93% of total COD and 71.4% of total NH₄⁺–N removal, with COD removal ratio 26.9% higher than equivalent activated carbon layer alone

    So what. Concentrate anode design and biofilm support in the upper anode zone to maximize organic oxidation and ammonia removal before water reaches the cathode

  • Mechanism Nitrification in the downflow anode region produced NO₃⁻–N accounting for 49.02% (closed-circuit) and 46.12% (open-circuit) of NH₄⁺–N removal, followed by denitrification to 75.13% (closed) vs 66.47% (open)

    So what. Design the downflow zone for nitrification with oxygen from plant roots, then rely on anoxic zones and denitrifying bacteria in the cathode region to complete nitrogen removal; closed-circuit operation enhances denitrification by 8.66 percentage points

  • Trade-off Closed-circuit operation improved COD removal by 14.94 percentage points (79.65% vs 64.71%) and NH₄⁺–N removal by 57.6% relative improvement, attributed to anode acting as temporary electron acceptor

    So what. Operating in closed-circuit mode with external load is essential for maximizing both organic and nitrogen removal; the bioelectrochemical pathway enhances anaerobic biodegradation

  • Threshold Internal resistance of 463.66 Ω was theoretically close to external resistance of 450 Ω, enabling high power density of 456 mW/m³ at 22.5 mA/m² current density

    So what. Match external load resistance to internal resistance to maximize power output; the continuous water flow and high electrode conductivity minimize ohmic losses

  • Performance Voltage stabilized in two phases: first stable phase at ~6 days, second stable phase at ~18 days total, with stable operation range 598–713 mV during the 92-day study

    So what. Allow 18 days startup time for biofilm maturation and microbial community establishment before relying on stable power output; expect voltage fluctuations of ±57.5 mV during steady operation

Opportunity areas6

Specific gaps in this paper, with an experiment that would close each.

  • High No measurement of N₂O or NO accumulation during denitrification despite high NO₃⁻–N reduction (75.13%)

    The paper reports substantial denitrification but does not quantify whether N₂O is produced as an intermediate or final product. Section 3.2 states 'The NO₃⁻–N decreased from its highest concentration at 70.62 mg/L...to its lowest concentration at 17.56 mg/L' but does not account for the nitrogen mass balance or specify the end product (N₂ vs N₂O)

    Try. Measure N₂O and NO in gas phase above cathode and in effluent using gas chromatography or FTIR; vary cathode potential and dissolved oxygen to determine operating window that maximizes N₂ production and minimizes N₂O

  • High No systematic variation of cathode potential or dissolved oxygen concentration to optimize denitrification selectivity

    The paper operates with a fixed external resistance (1000 Ω) and relies on passive aeration via plant roots and air cathode. Section 3.2 mentions 'aerobic denitriers...could use both oxygen and nitrate as terminal electron acceptors' but does not test how cathode potential or DO affects the balance between aerobic and anaerobic denitrification pathways

    Try. Vary external resistance (100–10,000 Ω) or apply controlled cathode potential (−0.2 to +0.2 V vs Ag/AgCl) while measuring NO₃⁻–N, NO₂⁻–N, N₂O, and N₂ production; determine the potential window that maximizes complete denitrification to N₂

  • Medium No measurement of nitrite (NO₂⁻–N) accumulation or transient dynamics during nitrification–denitrification coupling

    The paper measures only NH₄⁺–N and NO₃⁻–N, not NO₂⁻–N. Section 3.2 describes nitrification producing NO₃⁻–N but does not report whether NO₂⁻–N accumulates as an intermediate, which could indicate incomplete nitrification or inhibition of nitrite oxidizers

    Try. Add NO₂⁻–N to the sampling protocol at all ports (influent, S1–S8, effluent); measure daily during steady state to detect transient accumulation under varying inlet loads

  • Medium No variation of hydraulic retention time (HRT) or organic loading rate to determine the operating window for simultaneous nitrification–denitrification

    The system operates at a fixed HRT of 2 days and inlet COD of 324–708 mg/L. Section 3.1 states 'The MFCs and IVCW-MFCs operate more efficiently under a lower organic matter load' but does not test the trade-off between COD removal, nitrogen removal, and power generation across a range of HRTs (0.5–5 days) or C/N ratios

    Try. Operate parallel reactors at HRT 0.5, 1, 2, 3, 5 days with constant inlet COD or varying C/N ratio (5:1 to 20:1 by mass); measure COD, NH₄⁺–N, NO₃⁻–N, NO₂⁻–N, N₂O, and power density to identify the optimal HRT for nitrogen removal without sacrificing power output

  • Medium No measurement of catholyte pH or anode pH dynamics, despite mention of pH gradient effects on power generation

    Section 3.3 states 'a continuous influx was used in this experiment; the wastewater flowed from anode to cathode while transporting protons, shortening the pH gradient between the two points and avoiding the small effect of electricity production caused by excess acidity at the anode or excess alkalinity at the cathode' but no pH data are provided

    Try. Install pH probes at anode inlet, anode outlet, cathode inlet, and cathode outlet; measure pH daily during steady state and correlate with voltage output and nitrogen species concentrations to quantify the pH gradient effect on power generation and nitrification–denitrification balance

  • Medium No characterization of the microbial community in the cathode region or comparison of anode vs cathode communities under closed-circuit vs open-circuit operation

    Section 2.3 states 'the substrate-attached biolms from these two regions were sampled for microbial community analysis' and Section 3.3 mentions Geobacter and Desulfuromonas in the anode, but the results section does not present cathode community data or compare the two circuits

    Try. Perform 16S rRNA sequencing on anode and cathode biofilms from both closed-circuit and open-circuit reactors; quantify the relative abundance of nitrifiers (Nitrosomonas, Nitrobacter), denitrifiers (Paracoccus, Pseudomonas), and electrochemically active bacteria (Geobacter, Desulfuromonas) to identify which taxa drive the 14.94% COD and 57.6% NH₄⁺–N improvement in closed-circuit mode

Generated by MESSAI extraction pipeline · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 65 extracted values

Select a citation to see the quote, page and confidence behind a value.

35 of 65 extracted rows modelable

  • 27 not canonicalised (no canonical slug)
  • 2 no SI value
  • 1 contradicts other papers
ParameterValueUnitConfidenceSourceNotesModelable
Chemical Oxygen Demand (COD) Removal64.7%95%
potassium dichromate method
"After stable treatment with a two-day HRT, the average effluent concentration of…" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateModelable
Electrode Surface Area10cm95%
extracted
"the anode adopted a stainless-steel wire mesh to wrap the activated carbon parti…" · T=33°CExcluded: no SI value
Chemical Oxygen Demand (COD) Concentration103mg/L95%
potassium dichromate method
"After stable treatment with a two-day HRT, the average effluent concentration of…" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateModelable
Chemical Oxygen Demand (COD) Concentration708mg/L95%
potassium dichromate method
"the influent COD concentrations varied from 324–708 mg L1" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateModelable
Chemical Oxygen Demand (COD) Concentration505mg/L95%
potassium dichromate method
"the influent COD concentrations varied from 324–708 mg L1, and the average conce…" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateModelable
Electrode Surface Area20cm95%
extracted
"Carbon felt was used as the cathode (20 cm × 20 cm)" · T=33°CExcluded: no SI value
Temperature33 ± 5 (range)°C95%
extracted
"the average temperature during the entire period of operation, which occurred in…" · T=33°CModelable
Chemical Oxygen Demand (COD) Removal79.7%95%
potassium dichromate method
"The average chemical oxygen demand (COD) and ammonia nitrogen (NH4+–N) removal e…" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateModelable
Ammonia nitrogen (NH4+–N) removal efficiency77.5%95%
sodium reagent method
"The average chemical oxygen demand (COD) and ammonia nitrogen (NH4+–N) removal e…" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateExcluded: not canonicalised (no canonical slug)
Influent NH4+–N concentration (average)215mg/L95%
sodium reagent method
"the inflow NH4+–N concentrations varied from 138–284 mg L1, with an average conc…" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateExcluded: not canonicalised (no canonical slug)
Influent NH4+–N concentration (range low)138mg/L95%
sodium reagent method
"the inflow NH4+–N concentrations varied from 138–284 mg L1" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateExcluded: not canonicalised (no canonical slug)
Influent NH4+–N concentration (range high)284mg/L95%
sodium reagent method
"the inflow NH4+–N concentrations varied from 138–284 mg L1" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateExcluded: not canonicalised (no canonical slug)
NH4+–N removal efficiency (closed-circuit)77.5%95%
sodium reagent method
"The average removal rate of IVCW-MFC-C reached 77.5%, which was higher than that…" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateExcluded: not canonicalised (no canonical slug)
Output voltage range (stable operation)598mV95%
data logger (ads1115 and ch341a logger)
"In the stable operation period, the output voltage of the system was in the rang…" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateExcluded: not canonicalised (no canonical slug)
Output voltage range (stable operation)713mV95%
data logger (ads1115 and ch341a logger)
"In the stable operation period, the output voltage of the system was in the rang…" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateExcluded: not canonicalised (no canonical slug)
Reactor cross-section dimensions40cm95%
extracted
"with a square cross-section of 40 × 20 cm" · T=33°CExcluded: not canonicalised (no canonical slug)
Daily wastewater flow rate5.75L/d95%
extracted
"each CW-MFC treated 5.75 L of swine wastewater daily with an HRT of two days" · T=33°C, substrate=swine wastewater, HRT=48hExcluded: not canonicalised (no canonical slug)
Chemical Oxygen Demand (COD) Concentration181mg/L95%
potassium dichromate method
"After stable treatment with a two-day HRT, the average effluent concentration of…" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateModelable
Reactor Volume Total37.8L95%
extracted
"The volume of the whole container was 37.8 L, with an effective volume of 11.5 L…" · T=33°CModelable
Voltage713mV95%
data logger (ads1115 and ch341a logger)
"The peak values of the output voltage and power density were 713 mV and 456 mW m…" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateModelable
Reactor Volume11.5L95%
extracted
"The volume of the whole container was 37.8 L, with an effective volume of 11.5 L…" · T=33°CModelable
Reactor Height50cm95%
extracted
"the IVCW-MFC reactor was made of a 50 cm tall polyacrylic plastic box" · T=33°CModelable
Chemical Oxygen Demand (COD) Concentration324mg/L95%
potassium dichromate method
"the influent COD concentrations varied from 324–708 mg L1" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateModelable
Cell Doubling Time92d95%
extracted
"The swine wastewater was provided for 92 consecutive days." · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateModelable
NO3–N concentration (highest, open-circuit)70.3mg/L90%
phenol-2-sulfonic acid method
"The NO3–N decreased from its highest concentration at 70.62 mg L1 (IVCW-MFC-C) a…" · T=33°C, substrate=swine wastewater, HRT=48h, steady_stateExcluded: not canonicalised (no canonical slug)
Showing 25 of 65

Methodology

What was the system and how was it run

Methodology

Methodology

The IVCW-MFC reactor (50 cm tall, 40×20 cm cross-section, 11.5 L effective volume) was divided into downflow and upflow zones by a partition with a 5 cm unblocked gap at the bottom. The anode (stainless-steel mesh wrapping activated carbon, 20×20×10 cm) was buried in the downflow zone (30–40 cm depth); the cathode (carbon felt, 20×20 cm) was placed on the upflow surface. Activated carbon layers (5 cm height) were installed in both zones. The system was inoculated with anaerobic digestion sludge and operated for ~1 month before testing. Real swine wastewater (post-biogas treatment) was fed continuously at 5.75 L/day (HRT 2 days) for 92 days. Closed-circuit (IVCW-MFC-C) and open-circuit (IVCW-MFC-O) modes were operated in parallel (n=3 each). Samples were collected every 2 days from 8 ports (S1–S8) plus influent and effluent, analyzed for COD (dichromate method), NO₃⁻–N and NH₄⁺–N (phenol-sulfonic acid and sodium reagent methods). Voltage was logged every 6 minutes; polarization curves were measured at end-of-study to determine power density and internal resistance. Microbial communities were characterized by 16S rRNA sequencing (Illumina MiSeq, V3–V4 region) of anode and cathode biofilms.

System configuration

FieldValue
reactor typeMES
chamber config2-chamber

Operating conditions

10 runs extracted
RunT°CpHanpHcatSubstrate[S]mg/LHRThModeR_extΩV_appVInoculum
v2-19eaff737f7d700a33——swine wastewater50548————
v2-1f6602261d63acaa28——glucose with ammonium chloride700—startup———
v2-2fcf07ec0989324433——swine wastewater50548steady_state———
v2-36823d77049999a933——swine wastewater50548startup1000——
v2-679b5d3d48f421f133——swine wastewater70848steady_state———
v2-7c3a638b1d1fb0fa33——swine wastewater21548steady_state1000——
v2-9f2a5e3fe4309ae033—————————
v2-aa712c306b8d848833——swine wastewater50548steady_state1000——
v2-ce46d75f6624075433——swine wastewater32448steady_state———
v2-d3c939418229758228——glucose700—startup———

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

AI confidence

72%

Model self-reported confidence

Mean parameter confidence

90%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

07

Source PDF

The paper as published.

loading 3D model…

Representative model, generic MFC

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

MFC
System
0.02amperes per square metre
Best result · Current density
65
Extracted values
2019
Year

Keywords

  • Ammonia
  • Wetland
  • Microbial fuel cell
  • Organic matter
  • Process (computing)
  • Constructed wetland

Cite

Feng Liu, Lei Sun, Jinbao Wan et al. (2019). Organic matter and ammonia removal by a novel integrated process of constructed wetland and microbial fuel cells. RSC Advances. https://doi.org/10.1039/c8ra10625h

PubMed
35515927

Open in lab for full controls, parameter editing, and template overlays.

Open in lab