Research

Paper · MEC

Application of voltage to enrich anaerobic ammonium-oxidizing bacteria from mixed cultures for the degradation of actual wastewater containing COD.

01

Summary

What the paper reports, in its own words.

3D Interactive ModelAI Enhanced· 75%

Abstract

Anaerobic ammonium-oxidizing bacteria (AnAOB) present significant enrichment challenges due to slow growth kinetics and extended cultivation periods. This study employed single-chamber microbial electrolysis cells (MECs) to investigate substrate conversion rates, microbial community dynamics, and bacterial morphological adaptations in mixed consortia (incorporating nitrifiers, denitrifiers, and AnAOB) under varying applied voltages (0-1.2 V). Key results demonstrated that at 0.6 V, ammonium removal efficiency nearly doubled compared to the 0 V baseline, with AnAOB relative abundance increasing from 5.78 ± 0.38% to 12.34 ± 0.60% while denitrifiers decreased from 9.69 ± 1.33% to 2.84 ± 0.14%. Voltage escalation to 1.2 V induced proliferation of denitrifiers, which coexisted with AnAOB under carbon-limited conditions. During actual wastewater operation, ammonium degradation rates declined to 73% (Cycle 1) and 68% (Cycle 2), yet AnAOB maintained functional dominance at 12.56 ± 0.40% relative abundance. These findings provide valuable insights for AnAOB enrichment from complex communities, demonstrating voltage optimization's potential to enhance syntrophic interactions and intensify nitrogen removal pathways.

AI summary

75% confidence

This MEC study investigates Anaerobic ammonium oxidation, Carbon metabolism, Microbial community. Key performance metrics include voltage output.

Generated by MESSAI extraction pipeline · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 3 extracted values

Select a citation to see the quote, page and confidence behind a value.

0 of 3 extracted rows modelable

  • 2 not canonicalised (no canonical slug)
  • 1 no SI value
ParameterValueUnitConfidenceSourceModelable
Reactor typesingle-chamber—80%
extracted
Excluded: not canonicalised (no canonical slug)
Chambers1—80%
extracted
Excluded: not canonicalised (no canonical slug)
Substratewastewater—70%
extracted
Excluded: no SI value

Methodology

What was the system and how was it run

Methodology

Methodology

The study utilized single-chamber microbial electrolysis cells (MECs) with varying applied voltages to enrich anaerobic ammonium-oxidizing bacteria (AnAOB) from mixed cultures for the degradation of actual wastewater containing COD.

Operational parameters

FieldValue
substrate["wastewater"]

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

25%

Fraction of expected parameters extracted

Data completeness

50%

Overall extraction coverage across fields

AI confidence

75%

Model self-reported confidence

Mean parameter confidence

77%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

loading 3D model…

Representative model, generic MEC

Representative MEC — matched on the paper’s system type only, not its reactor or geometry.

MEC
System
3
Extracted values
2025
Year

Keywords

  • Anaerobic ammonium oxidation
  • Carbon metabolism
  • Microbial community
  • Microbial electrolysis
  • Nitrogen removal

Cite

(2025). Application of voltage to enrich anaerobic ammonium-oxidizing bacteria from mixed cultures for the degradation of actual wastewater containing COD. Environmental monitoring and assessment. https://doi.org/41231292

PubMed
41231292

Open in lab for full controls, parameter editing, and template overlays.

Open in lab