The tail wastewater from sewage treatment facilities usually lacks carbon sources, and its subsequent treatment for deep nitrogen removal is difficult in natural conditions. In this study, the constructed wetland (CW) was integrated with microbial fuel cell (MFC) with high-density polyethylene (HDPE) fillers as the main matrix to improve nitrogen removal under inefficient carbon source conditions. Compared with the regular MFC and CW systems, MFC-CW attained higher nitrogen removal under low-carbon source conditions. The influence of influent carbon/nitrogen ratio (C/N) on the denitrification and electricity-generation performance was explored. Although the increase of carbon source simultaneously improved chemical oxygen demand (COD), ammonia (NH4+-N), nitrate (NO3−-N) and TN removal, the power generation during the carbon source adjustment showed low relation with the variation of influent COD in the range of 40–120 mg/L. CW was more dependent on carbon sources, and the addition of bioelectrochemical systems into MFC-CW could reduce the dependence of nitrogen removal on carbon sources, especially under low carbon source conditions. These findings offer valuable insights into the potential applications of MFC-CW for tail water treatment, and its parameters for utilization in real CWs should be explored in future studies.

AI summary

78% confidence

This study integrated a microbial fuel cell (MFC) with a constructed wetland (CW) using HDPE fillers to treat low-carbon tail wastewater. The MFC-CW system achieved 73.91% total nitrogen removal in steady state, outperforming standalone CW (63.88%) and MFC (68.65%). Nitrogen removal improved with increasing C/N ratio up to 8, but power output remained insensitive to COD variation between 40–120 mg/L. The bioelectrochemical coupling reduced carbon-source dependence for denitrification compared to passive wetlands, making it suitable for nutrient-limited secondary effluent polishing.

Key insights

  • Performance MFC-CW achieved 73.91% TN removal versus 63.88% in CW alone during steady state, a 10 percentage-point gain driven by electrochemical enhancement of denitrification.

    So what. Integrate electrodes into wetlands treating low-carbon effluent to recover 10+ percentage points of nitrogen removal without adding external carbon.

  • Threshold NO₃⁻-N removal reached nearly 100% when C/N ≥ 4, but at C/N = 2.67 denitrification was severely limited, indicating a threshold below which carbon becomes rate-limiting.

    So what. Operate MFC-CW systems at C/N ≥ 4 to avoid NO₃⁻-N accumulation; below this threshold, supplement carbon or rely on electrochemical reduction at the cathode.

  • Trade-off CW TN removal increased 35.8 percentage points (50.08% → 85.88%) when C/N rose from 2.67 to 5.33, while MFC-CW increased only 16.5 points (57.28% → 73.77%), showing MFC-CW is 2.2× less carbon-dependent.

    So what. Use MFC-CW for low-C/N wastewaters (2.67–4) where passive CW fails; the electrochemical pathway supplies electrons for denitrification independent of organic carbon.

  • Threshold Output voltage and power density showed minimal response to COD increase from 40–120 mg/L (average ~100 mV, max power 0.23–0.83 mW/m²), indicating power is not limited by carbon in this low-load regime.

    So what. Do not expect power output to scale with carbon addition in low-COD tail waters; focus on electrode kinetics and internal resistance (1150–2211 Ω) rather than substrate availability.

  • Trade-off Water hyacinth planting reduced MFC-CW power density below that of non-planted MFC (max 0.83 vs 1 mW/m²), likely due to excessive root exudates and oxygen transfer interfering with cathode potential.

    So what. If power generation is a priority, minimize plant root density or use slower-growing species; if nitrogen removal is the goal, accept the power trade-off for improved nitrification via plant-mediated aeration.

Opportunity areas6

Specific gaps in this paper, with an experiment that would close each.

  • High No measurement of N₂O or NO₂⁻ accumulation across the C/N range (2.67–8). Incomplete denitrification to N₂ could mask true nitrogen removal and reveal incomplete reduction pathways.

    Paper reports NO₃⁻-N removal but not speciation of end products; at low C/N or high current, cathode potential may favor NO₂⁻ accumulation or N₂O slip rather than complete reduction to N₂.

    Try. Gas chromatography or ion chromatography for N₂O, NO₂⁻, and NO₃⁻ at C/N 2.67, 4, 5.33, 6.67, 8 to map the denitrification pathway and identify optimal potential window.

  • High No direct measurement of cathode and anode potentials (vs. Ag/AgCl or SHE). Only external voltage and internal resistance reported; electrode potentials are unknown.

    Cathode potential controls denitrification selectivity and N₂O formation; anode potential affects organic oxidation efficiency. Paper states external resistance was 1000 Ω but does not report actual electrode potentials, limiting mechanistic understanding.

    Try. Potentiostat-controlled experiments at fixed cathode potentials (e.g., −0.2, −0.4, −0.6 V vs. Ag/AgCl) across C/N range to map NO₃⁻ reduction, NO₂⁻ accumulation, and N₂O production.

  • Medium Hydraulic retention time (HRT) fixed at 2 days; no variation tested. Unclear whether nitrogen removal is limited by contact time or by carbon/electron availability.

    At low C/N, longer HRT might allow more complete denitrification; at high C/N, shorter HRT might reduce cost. Paper does not explore this trade-off.

    Try. Test HRT 1, 2, 4 days at C/N 2.67 and 5.33 to determine whether nitrogen removal is kinetically or thermodynamically limited.

  • Medium Dissolved oxygen (DO) in cathode region reported as 1.5–2.5 mg/L but not correlated with nitrification rate or ammonia removal. Unclear whether this DO level is optimal or limiting.

    Nitrification requires DO; excess DO may suppress denitrification. Paper mentions DO range but does not test its effect on nitrogen speciation or removal kinetics.

    Try. Vary plant density or aeration to control cathode DO (0.5–5 mg/L) and measure NH₄⁺-N oxidation rate and NO₃⁻ production to find optimal DO window.

  • Medium Catholyte pH not reported. Denitrification kinetics and N₂O formation are pH-sensitive; pH drift could explain power and removal variations.

    Paper measures influent/effluent water quality but does not report pH or pH gradient across the system. Cathode pH can drift due to proton consumption during denitrification.

    Try. Monitor pH in anode, cathode, and bulk liquid across C/N range; test pH control (e.g., buffer addition) to isolate pH effects on nitrogen removal and power output.

  • Low No comparison of HDPE filler performance against other high-surface-area materials (e.g., activated carbon, biochar, ceramic). SEM shows biofilm growth but not quantified.

    Paper claims HDPE (500 m²/m³) is superior to gravel but does not benchmark against other fillers or quantify biofilm thickness/density.

    Try. Parallel reactors with HDPE, activated carbon, biochar, and ceramic at C/N 4 and 8; measure biofilm biomass (MLVSS) and compare nitrogen removal and power output.

Generated by MESSAI extraction pipeline · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 53 extracted values

Select a citation to see the quote, page and confidence behind a value.

46 of 53 extracted rows modelable

  • 1 not canonicalised (no canonical slug)
  • 2 no SI value
  • 3 verifier rejected the value
  • 1 contradicts other papers
ParameterValueUnitConfidenceSourceNotesModelable
Power Density0.23mW/m²90%
extracted
"As shown in Figure 8, the MFC-CW system achieved the maximum current density in …" · substrate=tail wastewater, HRT=48hModelable
Voltage55mV90%
extracted
"In the first stage (0–7 days), the output voltage of the MFC-CW and MFC systems …" · substrate=tail wastewater, HRT=48hModelable
Voltage107mV90%
extracted
"In the third stage (18–25 days), the average output voltage of the MFC-CW and MF…" · substrate=tail wastewater, HRT=48hModelable
Voltage60mV90%
extracted
"In the first stage (0–7 days), the output voltage of the MFC-CW and MFC systems …" · substrate=tail wastewater, HRT=48hModelable
Voltage89mV90%
extracted
"In the second stage (8–17 days), the average output voltage of the MFC-CW and MF…" · substrate=tail wastewater, HRT=48hModelable
Current Density5mA/m²90%
extracted
"As shown in Figure 8, the MFC-CW system achieved the maximum current density in …" · substrate=tail wastewater, HRT=48hModelable
Internal Resistance1,640ohm90%
extracted
"In MFC, the internal resistances were 1635.6, 1623.8, 1466.8, 1578.2, and 1485.4…" · substrate=tail wastewater, HRT=48hModelable
Power Density1mW/m²90%
extracted
"The MFC system attained the maximum power density at a C/N of 5.33." · substrate=tail wastewater, HRT=48hExcluded: verifier rejected the value
Internal Resistance2,210ohm90%
extracted
"The internal resistances of MFC-CW at C/N of 2.67, 4, 5.33, 6.67, and 8 were 115…" · substrate=tail wastewater, HRT=48hModelable
Internal Resistance1,680ohm90%
extracted
"The internal resistances of MFC-CW at C/N of 2.67, 4, 5.33, 6.67, and 8 were 115…" · substrate=tail wastewater, HRT=48hModelable
Power Density0.83mW/m²90%
extracted
"The maximum power density of the MFC-CW system was realized at the C/N of 6.67, …" · substrate=tail wastewater, HRT=48hExcluded: verifier rejected the value
Voltage123mV90%
extracted
"In the third stage (18–25 days), the average output voltage of the MFC-CW and MF…" · substrate=tail wastewater, HRT=48hModelable
Voltage83mV90%
extracted
"In the second stage (8–17 days), the average output voltage of the MFC-CW and MF…" · substrate=tail wastewater, HRT=48hModelable
Power Density0.23mW/m²90%
extracted
"the maximum current density and power density of the MFC system were in the rang…" · substrate=tail wastewater, HRT=48hModelable
Internal Resistance1,150ohm90%
extracted
"The internal resistances of MFC-CW at C/N of 2.67, 4, 5.33, 6.67, and 8 were 115…" · substrate=tail wastewater, HRT=48hModelable
Current Density5mA/m²90%
extracted
"the maximum current density and power density of the MFC system were in the rang…" · substrate=tail wastewater, HRT=48hModelable
Internal Resistance1,790ohm90%
extracted
"The internal resistances of MFC-CW at C/N of 2.67, 4, 5.33, 6.67, and 8 were 115…" · substrate=tail wastewater, HRT=48hModelable
Internal Resistance1,470ohm90%
extracted
"In MFC, the internal resistances were 1635.6, 1623.8, 1466.8, 1578.2, and 1485.4…" · substrate=tail wastewater, HRT=48hModelable
Internal Resistance2,030ohm90%
extracted
"The internal resistances of MFC-CW at C/N of 2.67, 4, 5.33, 6.67, and 8 were 115…" · substrate=tail wastewater, HRT=48hModelable
Nitrogen Removal63.9%90%
extracted
"In the third stage (18–25 days), the TN removals of the three systems fluctuated…" · substrate=tail wastewater, HRT=48hModelable
Chemical Oxygen Demand (COD) Removal88%90%
extracted
"In the third stage (18–25 days), the COD removals of the three systems appeared …" · substrate=tail wastewater, HRT=48hModelable
Nitrogen Removal63.9%90%
extracted
"In the steady state of the system, the average TN removal of the three systems w…" · substrate=tail wastewater, HRT=48h, steady_stateModelable
Chemical Oxygen Demand (COD) Removal46.3%90%
extracted
"In the first stage (0–7 days), the COD removal of the three systems fluctuated f…" · substrate=tail wastewater, HRT=48hModelable
Chemical Oxygen Demand (COD) Removal83.4%90%
extracted
"In the second stage (8–17 days), the COD removals of the three systems were in a…" · substrate=tail wastewater, HRT=48hModelable
Chemical Oxygen Demand (COD) Removal77.6%90%
extracted
"In the second stage (8–17 days), the COD removals of the three systems were in a…" · substrate=tail wastewater, HRT=48hModelable
Showing 25 of 52

Methodology

What was the system and how was it run

Methodology

Methodology

Three parallel systems (CW, MFC, MFC-CW) were operated in 40.25 L plexiglas cylinders with HDPE fillers (500 m²/m³) and graphite electrodes (anode and cathode at 1000 Ω external resistance). Influent COD was varied 40–120 mg/L (C/N 2.67–8) with TN ~15 mg/L at HRT 2 days. Effluent COD, NH₄⁺-N, NO₃⁻-N, and TN were measured by standard methods; voltage and polarization curves were recorded; biofilm was imaged by SEM before and after 25-day startup.

Operating conditions

13 runs extracted
RunT°CpHanpHcatSubstrate[S]mg/LHRThModeR_extΩV_appVInoculum
v2-043f41674a73a223———tail wastewater—48————
v2-0db15a079c4492c5———tail wastewater—48steady_state———
v2-171f2e5f129a7c90———tail wastewater—48—1000——
v2-2a53102ab3c2cb64———tail wastewater—48————
v2-2b7ce69addb7140d———tail wastewater—48—1000——
v2-3536f8e759e94d54———tail wastewater—48—1000——
v2-517bf1a3efa2ad7a———tail wastewater—48————
v2-53f21cc35a31bd26———tail wastewater—48steady_state1000——
v2-6f2a27f1b432de68———tail wastewater—48—1000——
v2-a09c501724ccd75d———tail wastewater—48—1000——
v2-a33399ebb015982c———tail wastewater—48————
v2-e4db8dc73d883648———tail wastewater—48—1000——
v2-edb8fddd65071e36———tail wastewater—48————

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

AI confidence

78%

Model self-reported confidence

Mean parameter confidence

90%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

07

Source PDF

The paper as published.

loading 3D model…

Representative model, generic MFC

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

MFC
System
1.00milliwatts per square metre
Best result · Power density
best of 4
53
Extracted values
2023
Year

Keywords

  • Carbon fibers
  • Denitrification
  • Microbial fuel cell
  • Nitrogen
  • Sewage treatment
  • Wastewater

Cite

Yu Kong, Jing Hu, Xiwu Lü et al. (2023). Effects of Carbon Source on Denitrification and Electricity Generation in Composite Packing MFC-CW for Tail Water Treatment. Water. https://doi.org/10.3390/w15244285

Journal
Water

Open in lab for full controls, parameter editing, and template overlays.

Open in lab