Research

Paper · MEC

Combined anaerobic - aerobic bioelectrochemical system for ammonium sulfide and carbon removal from ethanol stillage

01

Summary

What the paper reports, in its own words.

3D Interactive ModelAI Enhanced· 72%

AI summary

72% confidence

This study integrated a two-chamber bioelectrochemical system (BES) with anaerobic and aerobic bioreactors to treat ethanol stillage, comparing five operating modes: no BES, MFC, and MEC at 0.6, 0.8, and 1.0 V. MEC at 1.0 V achieved 94.1% COD removal and 90.91% NH4+-N removal, with methane content rising from 57% (no BES) to 74% (MEC). Sulfate removal reached 100% in MEC modes versus 8.74% without BES. The cation exchange membrane enabled ammonium migration to the cathode where nitrification and denitrification occurred, improving both energy recovery and pollutant removal.

Key insights

  • Threshold Applied voltage directly controls ammonium removal efficiency: 1.0 V achieved 90.91% NH4+-N removal versus 53.58% without BES, a 1.7× improvement.

    So what. Operators targeting high ammonia recovery should apply ≥0.8 V external voltage; below 0.6 V, removal plateaus near 67–69%.

  • Threshold Sulfate removal shows a sharp on/off transition: MFC achieved 72.71% SO4²⁻ removal, but all three MEC modes achieved 100% removal regardless of voltage (0.6–1.0 V).

    So what. Sulfide oxidation at the anode is voltage-independent above ~0.6 V; MEC operation is sufficient for complete sulfate removal without voltage optimization.

  • Trade-off COD removal efficiency increases with applied voltage in MEC but plateaus in MFC: MEC1.0V achieved 94.1% versus MFC's 69.82%, a 1.35× gain.

    So what. For maximum organic matter degradation, use MEC at ≥0.8 V; MFC mode offers minimal advantage over anaerobic digestion alone (69.82% vs 56.57%).

  • Threshold Methane content improves in all BES modes but saturates: MFC reached 70 vol.%, MEC0.6V 72%, and MEC0.8V/1.0V both 74%, suggesting a ceiling near 74%.

    So what. Biogas quality improvement plateaus at MEC0.6V; higher voltages improve COD/NH4+ removal but not gas composition further.

  • Mechanism Current density scales linearly with applied voltage in MEC but remains low in MFC: MEC1.0V reached 1.5–2.9 A/m² versus MFC's 0.01–0.02 A/m², a 100–150× difference.

    So what. MEC operation drives substantially higher electron transfer rates; if anode biofilm kinetics are limiting, MEC will unlock higher throughput than MFC.

Opportunity areas6

Specific gaps in this paper, with an experiment that would close each.

  • High No measurement of nitrite (NO2⁻) or N2O accumulation in cathode or aerobic reactor effluent despite nitrification/denitrification occurring.

    Paper states 'nitrification in the zone of the aerobic bioreactor' and 'nitrate reduction takes place' at cathode, but provides no data on intermediate nitrogen oxides. N2O is a potent greenhouse gas and nitrite can inhibit methanogenesis.

    Try. Measure NO2⁻ and N2O in aerobic reactor outlet and cathode effluent across 0.6–1.0 V range; quantify by ion chromatography and gas chromatography.

  • High No systematic variation of cathode pH or dissolved oxygen (DO) in aerobic reactor; both are known to control nitrification/denitrification selectivity.

    Paper reports 'pH 7.5–7.6' as fixed input but does not report cathode pH or aerobic reactor DO. Nitrification rate and N2O yield are highly pH and DO sensitive.

    Try. Vary cathode pH (6.5–8.5) and aerobic reactor DO (2–8 mg/L) at fixed 0.8 V; measure NH4⁺ removal, NO3⁻ accumulation, and N2O flux.

  • Medium No exploration of C/N ratio effects; ethanol stillage has fixed TKN (302–315 mg/L) but only one dilution tested.

    Paper dilutes stillage 4× to achieve ~10 g/L COD but does not test whether lower or higher C/N ratios improve nitrogen removal or reduce N2O.

    Try. Test 2×, 4×, and 8× dilutions (varying C/N from ~30 to ~120 on COD:TKN basis); measure NH4⁺ removal and NO3⁻/NO2⁻ accumulation at 0.8 V.

  • Medium No measurement of anode or cathode potential (vs. Ag/AgCl or SHE); only external voltage applied is reported.

    Paper applies 0.6–1.0 V external voltage but does not report actual electrode potentials. Anode potential controls sulfide oxidation pathway (S⁰ vs. SO4²⁻); cathode potential controls denitrification selectivity (NO3⁻ → NO2⁻ → N2O → N2).

    Try. Insert reference electrodes; measure anode and cathode potential vs. Ag/AgCl at each external voltage; correlate with sulfide speciation and nitrogen product distribution.

  • Medium No investigation of HRT trade-offs; fixed 11-day anaerobic and 6-day aerobic HRT may not be optimal for nitrogen cycling.

    Paper states contact times but does not vary them. Shorter HRT may increase throughput but reduce nitrification/denitrification completeness; longer HRT may accumulate inhibitory ammonia.

    Try. Vary anaerobic HRT (5–15 days) and aerobic HRT (3–9 days) at 0.8 V; measure NH4⁺ removal, NO3⁻ accumulation, and methane yield.

  • Medium No characterization of biofilm composition or electroactive bacteria (EAB) abundance on anode/cathode; mechanism of improved removal is inferred but not verified.

    Paper attributes sulfide oxidation and COD removal to EAB but provides no 16S rRNA, qPCR, or microscopy data. Unclear whether Geobacter, Shewanella, or other taxa dominate.

    Try. Sample anode and cathode biofilms at days 3, 7, and 11; perform 16S rRNA gene sequencing and qPCR for known EAB; correlate abundance with current density and removal efficiency.

Generated by MESSAI extraction pipeline · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 201 extracted values

Select a citation to see the quote, page and confidence behind a value.

81 of 200 extracted rows modelable

  • 85 not canonicalised (no canonical slug)
  • 34 no SI value
ParameterValueUnitConfidenceSourceNotesModelable
Substrateethanol—80%
llm
Chemical oxygen demand (COD) anode zone0.9g/L90%
cod (hanna reagents, apha)
"COD anode 0.9 g/L (AD-MEC_0.8V)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Chemical oxygen demand (COD) removal efficiency69.8%90%
extracted
"When the BES works as an MFC, the COD removal efficiency is 69.82 %" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Sulfate removal efficiency72.7%90%
extracted
"SO42- content decreases by 72.71 % (MFC)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Methane content70vol %90%
extracted
"In MFC mode, the methane content rises to 70 %" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Chemical oxygen demand (COD) cathode zone1.15g/L90%
cod (hanna reagents, apha)
"COD cathode 1.152 g/L (AD-MFC)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Hydrogen sulfide liquid13.9mg/L90%
spectrophotometric (nanocolor test, 620 nm)
"H2S in liquid 13.89 mg/L (AD-MFC)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Hydrogen sulfide liquid4.65mg/L90%
spectrophotometric (nanocolor test, 620 nm)
"H2S in liquid 4.65 mg/L (AD-MEC_1.0V)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Ammonium cathode zone30.5mg/L90%
kjeldahl (udk 127)
"NH4+ cathode 30.5 mg/L (AD-MEC_0.8V)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Chemical oxygen demand (COD) cathode zone0.5g/L90%
cod (hanna reagents, apha)
"COD cathode 0.5 g/L (AD-MEC_0.8V)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Sulfate removal efficiency8.74%90%
extracted
"removal rate 8.74 % (without BES)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Chemical oxygen demand (COD) removal efficiency56.6%90%
extracted
"without BES ... only 56.57 %" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Ammonium removal efficiency53.6%90%
extracted
"without BES - only 53.58 %" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Ammonium anode zone125mg/L90%
kjeldahl (udk 127)
"NH4+ anode 125 mg/L (AD-MEC_0.8V)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Chemical oxygen demand (COD) anode zone2.78g/L90%
cod (hanna reagents, apha)
"COD anode 2.78 g/L (AD-MFC)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Chemical oxygen demand (COD) anode zone0.59g/L90%
cod (hanna reagents, apha)
"COD anode 0.59 g/L (AD-MEC_1.0V)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Ammonium removal efficiency90.9%90%
extracted
"best removal ... MEC 1.0 V (90.91 %)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Ammonium cathode zone45.5mg/L90%
kjeldahl (udk 127)
"NH4+ cathode 45.5 mg/L (AD-MEC_0.6V)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Ammonium anode zone139mg/L90%
kjeldahl (udk 127)
"NH4+ anode 139.1 mg/L (AD-MEC_0.6V)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Chemical oxygen demand (COD) removal efficiency91%90%
extracted
"91 % at MEC0.8V" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Chemical oxygen demand (COD) anode zone1.4g/L90%
cod (hanna reagents, apha)
"COD anode 1.4 g/L (AD-MEC_0.6V)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Chemical oxygen demand (COD) cathode zone0.098g/L90%
cod (hanna reagents, apha)
"COD cathode 0.098 g/L (AD-MEC_1.0V)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Ammonium anode zone109mg/L90%
kjeldahl (udk 127)
"NH4+ anode 108.9 mg/L (AD-MEC_1.0V)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Chemical oxygen demand (COD) cathode zone0.8g/L90%
cod (hanna reagents, apha)
"COD cathode 0.8 g/L (AD-MEC_0.6V)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Chemical oxygen demand (COD) cathode zone2.19g/L90%
cod (hanna reagents, apha)
"COD cathode 2.192 g/L (without_BES)" · pH(an)=7.5, substrate=Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor, HRT=264h, continuousExcluded: not canonicalised (no canonical slug)
Showing 25 of 133

Methodology

What was the system and how was it run

Methodology

Methodology

A two-chamber BES with cation exchange membrane (CMI-7000S) was integrated in series with an anaerobic digester (UASB, 3 L, 11-day HRT) and aerobic bioreactor (1.5 L, 6-day HRT). Ethanol stillage (diluted 4×, ~10 g/L COD, 302–315 mg/L TKN) was fed daily (273 mL/day). The anode received recirculated anaerobic effluent; the cathode received recirculated aerobic effluent. Five modes were tested: no BES (control), MFC (100 Ω load), and MEC at 0.6, 0.8, and 1.0 V external voltage. Measurements included COD, NH4⁺-N, SO4²⁻, H2S, biogas composition (CH4, CO2, H2, H2S), current density, and power density over 11 days.

System configuration

FieldValue
reactor typeBES
chamber config2-chamber

Operational parameters

FieldValue
substrate["ethanol"]

Operating conditions

11 runs extracted
RunT°CpHanpHcatSubstrate[S]mg/LHRThModeR_extΩV_appVInoculum
cma:AD-MEC_0.6V—7.5—Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor10264continuous100.6Aerobic and anaerobic activated sludge from 'Almagest' AD, Verinsko village, Bulgaria
cma:AD-MEC_0.8V—7.5—Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor10264continuous100.8Aerobic and anaerobic activated sludge from 'Almagest' AD, Verinsko village, Bulgaria
cma:AD-MEC_1.0V—7.5—Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor10264continuous101Aerobic and anaerobic activated sludge from 'Almagest' AD, Verinsko village, Bulgaria
cma:AD-MFC—7.5—Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor9.21264continuous100—Aerobic and anaerobic activated sludge from 'Almagest' AD, Verinsko village, Bulgaria
cma:without_BES—7.5—Ethanol stillage (winery vinasse), neutralized to pH 7.5 with NaOH and diluted 4x; fed to anaerobic (UASB) reactor9.21264continuous——Aerobic and anaerobic activated sludge from 'Almagest' AD, Verinsko village, Bulgaria
v2-11fcd14d69b1393a—7.5—ethanol stillage——steady_state100.6—
v2-2a37beaa2f183569—7.5—ethanol stillage——steady_state100.8—
v2-4b8991a5a38af0d4—7.5—ethanol stillage——steady_state101—
v2-58966c17a300ee9e—7.5—ethanol stillage——steady_state———
v2-6e28f9a9a1915b3c—7.5—ethanol stillage——steady_state100——
v2-f69fa4f4d22bbc06—7.5—ethanol stillage——startup100——

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

13%

Fraction of expected parameters extracted

Data completeness

30%

Overall extraction coverage across fields

AI confidence

72%

Model self-reported confidence

Mean parameter confidence

89%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

07

Source PDF

The paper as published.

loading 3D model…

Representative model, generic MEC

Representative MEC — matched on the paper’s system type only, not its reactor or geometry.

MEC
System
50100milliwatts per square metre
Best result · Power density
best of 2
201
Extracted values
2023
Year

Keywords

  • Stillage
  • Anaerobic exercise
  • Sulfide
  • Ethanol
  • Ammonium
  • Carbon fibers

Cite

Polina Velichkova, Anatoliy Angelov, Svetlana Bratkova (2023). Combined anaerobic - aerobic bioelectrochemical system for ammonium sulfide and carbon removal from ethanol stillage. Journal of Chemical Technology and Metallurgy. https://doi.org/10.59957/jctm.v58i2.53

Open in lab for full controls, parameter editing, and template overlays.