Research

Paper · MFC

Response Characteristics of Nitrifying Bacteria and Archaea Community Involved in Nitrogen Removal and Bioelectricity Generation in Integrated Tidal Flow Constructed Wetland-Microbial Fuel Cell

01

Summary

What the paper reports, in its own words.

3D Interactive ModelAI Enhanced· 78%

Abstract

This study explores nitrogen removal performance, bioelectricity generation, and the response of microbial community in two novel tidal flow constructed wetland-microbial fuel cells (TFCW-MFCs) when treating synthetic wastewater under two different chemical oxygen demand/total nitrogen (COD/TN, or simplified as C/N) ratios (10:1 and 5:1). The results showed that they achieved high and stable COD, NH 4 + -N, and TN removal efficiencies. Besides, TN removal rate of TFCW-MFC was increased by 5-10% compared with that of traditional CW-MFC. Molecular biological analysis revealed that during the stabilization period, a low C/N ratio remarkably promoted diversities of ammonia-oxidizing archaea (AOA) and ammonia-oxidizing bacteria (AOB) in the cathode layer, whereas a high one enhanced the richness of nitrite-oxidizing bacteria (NOB) in each medium; the dominant genera in AOA, AOB, and NOB were Candidatus Nitrosotenuis , Nitrosomonas , and Nitrobacter . Moreover, a high C/N ratio facilitated the growth of Nitrosomonas , while it inhibited the growth of Candidatus Nitrosotenuis . The distribution of microbial community structures in NOB was separated by space rather than time or C/N ratio, except for Nitrobacter . This is caused by the differences of pH, dissolved oxygen (DO), and nitrogen concentration. The response of microbial community characteristics to nitrogen transformations and bioelectricity generation demonstrated that TN concentration is significantly negatively correlated with AOA-shannon, AOA-chao, 16S rRNA V4-V5-shannon, and 16S rRNA V4-V5-chao, particularly due to the crucial functions of Nitrosopumilus , Planctomyces , and Aquicella . Additionally, voltage output was primarily influenced by microorganisms in the genera of Nitrosopumilus, Nitrosospira , Altererythrobacter , Gemmata , and Aquicella. This study not only presents an applicable tool to treat high nitrogen-containing wastewater, but also provides a theoretical basis for the use of TFCW-MFC and the regulation of microbial community in nitrogen removal and electricity production.

AI summary

78% confidence

This study operated two tidal-flow constructed wetland-microbial fuel cells (TFCW-MFCs) at C/N ratios of 10:1 and 5:1, achieving 82.4% and 79.3% total nitrogen removal respectively with 97.7–98.4% COD removal. High-throughput sequencing revealed that lower C/N ratio (5:1) promoted ammonia-oxidizing archaea (AOA) and ammonia-oxidizing bacteria (AOB) diversity in the cathode, while higher C/N (10:1) enriched nitrite-oxidizing bacteria (NOB). Power density was 25.78 mW/m² at C/N 10:1 and 16.97 mW/m² at C/N 5:1, with voltage declining after day 40 as denitrifiers outcompeted electrogens.

Key insights

  • Trade-off Lower C/N ratio (5:1) increased AOA and AOB diversity in the cathode layer, while higher C/N (10:1) enhanced NOB richness across all layers.

    So what. Operators targeting nitrification should use lower C/N ratios (5:1) to enrich AOA/AOB in aerobic zones; higher C/N (10:1) favors complete nitrification to NO₃⁻ but reduces overall TN removal.

  • Trade-off NO₃⁻-N removal was 52.2% at C/N 10:1 but only 36.7% at C/N 5:1, despite higher overall TN removal at 10:1, indicating incomplete denitrification and NO₃⁻ accumulation at low C/N.

    So what. Carbon limitation at C/N 5:1 blocks denitrification; operators must increase C/N or add external carbon source if NO₃⁻ removal is the target, accepting trade-off with AOA/AOB diversity.

  • Threshold Voltage output peaked around day 30 then declined by ~33% by day 90, correlating with enrichment of denitrifiers over electrogens in the anode.

    So what. Operators should expect power output to decline as the system matures; electrode spacing (25 cm here) and anode surface area may need optimization to maintain electrochemical activity against denitrifier competition.

  • Mechanism Tidal flow operation increased effluent DO to 4.8–5.3 mg/L (above influent), which suppressed NO₃⁻-N removal but enhanced COD removal and microbial diversity in cathode.

    So what. Tidal flow is excellent for nitrification and COD removal but creates an aerobic bias that limits denitrification; consider anoxic zones or longer resting phases to enable NO₃⁻ reduction.

  • Performance Hydraulic retention time of 0.77 d (18.4 h total with recirculation) achieved 82.4% TN removal, outperforming most CW-MFCs at longer HRTs (1–4 d) reported in literature.

    So what. Short HRT is feasible for high-rate nitrogen removal in tidal systems; design for rapid cycling and oxygen transfer rather than long residence time.

Opportunity areas6

Specific gaps in this paper, with an experiment that would close each.

  • High No measurement of N₂O or N₂ production; paper reports NO₃⁻-N, NO₂⁻-N, and NH₄⁺-N removal but does not close the nitrogen mass balance or quantify gaseous losses.

    Text states 'TN removal rate' but does not specify whether TN is removed as N₂ (complete denitrification), N₂O (incomplete), or accumulated as NO₃⁻. Figure 2B shows TN removal but Figure 2D shows NO₃⁻ accumulation, implying a gap in the balance.

    Try. Install gas chromatography or membrane inlet mass spectrometry to measure N₂ and N₂O flux at anode and cathode under both C/N ratios; quantify the fraction of TN removed as gas versus accumulated as NO₃⁻.

  • High No cathode potential or anode potential measurement; paper reports voltage output but not the individual electrode potentials or current density distribution.

    Text reports 'maximum power densities' and 'current densities' but does not specify anode or cathode potential. This prevents understanding whether the cathode is operating in a denitrification window (−0.3 to −0.6 V vs SHE) or nitrification window (>+0.4 V).

    Try. Measure anode and cathode potential versus Ag/AgCl reference electrode during operation at both C/N ratios; correlate potential with NOB and denitrifier abundance; test if cathode potential can be controlled to favor denitrification over nitrification.

  • Medium No intermediate C/N ratios tested between 5:1 and 10:1; paper compares only two extremes, missing the optimal C/N for balancing TN removal, NO₃⁻ reduction, and power output.

    Text states 'the recommended optimal influent C/N ratio for the removal of nitrogen (from approximately 80% TN) by CW-MFC is 5.37' but this study tests only 5:1 and 10:1. Figure 2 shows NO₃⁻ removal increases with C/N, suggesting an optimum exists between 5 and 10.

    Try. Operate TFCW-MFC at C/N ratios of 6:1, 7:1, 8:1, and 9:1 for 90 days; measure TN, NO₃⁻-N, NO₂⁻-N removal, voltage, and microbial community (AOA, AOB, NOB) to identify the C/N that maximizes both TN removal and denitrification.

  • Medium No variation in tidal cycle parameters (flood duration, drain duration, rest duration); paper uses fixed 5 h flood, 12 min drain, 4 h rest, 2 h recirculation but does not test whether shorter or longer cycles affect nitrification/denitrification balance.

    Text states 'tidal flow operation' increases DO and TN removal, but does not isolate the effect of cycle frequency. Shorter cycles may increase oxygen transfer but reduce denitrification time; longer cycles may favor denitrification but reduce aeration.

    Try. Test tidal cycles of 3 h flood / 2 h rest, 5 h flood / 4 h rest (current), and 8 h flood / 8 h rest at C/N 7:1; measure DO profile, NO₃⁻-N removal, and denitrifier abundance to find the cycle that maximizes NO₃⁻ reduction.

  • Medium No measurement of pH in anode and cathode layers; paper reports effluent pH but not the spatial pH gradient, which drives nitrification and denitrification kinetics.

    Text states 'differences of pH, dissolved oxygen (DO), and nitrogen concentration' control NOB distribution, but only effluent pH is reported. Anode pH can drop to <6 (inhibiting AOB) and cathode pH can rise (favoring NOB).

    Try. Install pH probes in anode, cathode, and middle layers; measure pH profile during flood and drain phases at both C/N ratios; correlate local pH with AOA, AOB, NOB abundance.

  • Low No test of external carbon addition to boost NO₃⁻-N removal at low C/N; paper shows C/N 5:1 limits denitrification but does not test whether supplementing acetate or methanol can recover NO₃⁻ removal without changing the influent C/N ratio.

    Text states 'the loss of carbon source may lead to incomplete denitrification, thus causing the accumulation of NO₃⁻-N' but does not propose or test a remedy. This is a practical design option for operators.

    Try. At C/N 5:1, inject acetate or methanol into the anode layer at rates of 50, 100, and 200 mg/L; measure NO₃⁻-N removal, voltage, and denitrifier abundance to determine if external carbon can restore denitrification without inhibiting power output.

Generated by MESSAI extraction pipeline · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 21 extracted values

Select a citation to see the quote, page and confidence behind a value.

8 of 21 extracted rows modelable

  • 5 not canonicalised (no canonical slug)
  • 2 no SI value
  • 6 failed a physics check
ParameterValueUnitConfidenceSourceNotesModelable
Current Density0.18A/m²90%
extracted
"the current densities were 0.18 and 0.11 A/m2, respectively" · T=22°C, pH(an)=7.47, substrate=synthetic wastewater, HRT=18.4hExcluded: failed a physics check
Voltage40.3mV90%
extracted
"Device A and Device B had the average voltages of 40.25 and 26.85 mV, respective…" · T=22°C, pH(an)=7.47, substrate=synthetic wastewater, HRT=18.4hExcluded: failed a physics check
Power Density17mW/m²90%
extracted
"the maximum power densities of the system operated with C/N ratios of 10:1 and 5…" · T=22°C, pH(an)=7.34, substrate=synthetic wastewater, HRT=18.4hExcluded: failed a physics check
Internal Resistance151ohm90%
extracted
"the internal resistances were 151 and 174 , respectively" · T=22°C, pH(an)=7.47, substrate=synthetic wastewater, HRT=18.4hModelable
Power Density25.8mW/m²90%
extracted
"the maximum power densities of the system operated with C/N ratios of 10:1 and 5…" · T=22°C, pH(an)=7.47, substrate=synthetic wastewater, HRT=18.4hExcluded: failed a physics check
Internal Resistance174ohm90%
extracted
"the internal resistances were 151 and 174 , respectively" · T=22°C, pH(an)=7.34, substrate=synthetic wastewater, HRT=18.4hModelable
Current Density0.11A/m²90%
extracted
"the current densities were 0.18 and 0.11 A/m2, respectively" · T=22°C, pH(an)=7.34, substrate=synthetic wastewater, HRT=18.4hExcluded: failed a physics check
Voltage26.9mV90%
extracted
"Device A and Device B had the average voltages of 40.25 and 26.85 mV, respective…" · T=22°C, pH(an)=7.34, substrate=synthetic wastewater, HRT=18.4hExcluded: failed a physics check
Chemical oxygen demand (COD) removal load40.3g/m²·d90%
extracted
"The COD removal load of Device A was 40.26 g/m2·d, which was higher than that re…" · T=22°C, pH(an)=7.47, substrate=synthetic wastewater, HRT=18.4hExcluded: not canonicalised (no canonical slug)
NH4+-N removal rate95.9%90%
extracted
"The removal rates of NH4+-N in both devices were similar with values of higher t…" · T=22°C, pH(an)=7.47, substrate=synthetic wastewater, HRT=18.4hExcluded: no SI value
NO2−-N removal rate×290%90%
extracted
"the NO2−-N removal rates in both systems were more than 90%" · T=22°C, pH(an)=7.47, substrate=synthetic wastewater, HRT=18.4hExcluded: not canonicalised (no canonical slug)
NO3−-N removal rate52.2%90%
extracted
"The average removal rate of TN (82.39%) and NO3−-N (52.16%) in Device A were hig…" · T=22°C, pH(an)=7.47, substrate=synthetic wastewater, HRT=18.4hExcluded: not canonicalised (no canonical slug)
NH4+-N removal rate97.1%90%
extracted
"The removal rates of NH4+-N in both devices were similar with values of higher t…" · T=22°C, pH(an)=7.34, substrate=synthetic wastewater, HRT=18.4hExcluded: no SI value
NO3−-N removal rate36.7%90%
extracted
"The average removal rate of TN (82.39%) and NO3−-N (52.16%) in Device A were hig…" · T=22°C, pH(an)=7.34, substrate=synthetic wastewater, HRT=18.4hExcluded: not canonicalised (no canonical slug)
Dissolved Oxygen5.31mg/L90%
extracted
"The effluent DO in both Device A (5.31 mg/L) and Device B (4.83 mg/L) were higher …" · T=22°C, pH(an)=7.47, substrate=synthetic wastewater, HRT=18.4hModelable
Chemical Oxygen Demand (COD) Removal97.7%90%
extracted
"Device A and Device B were stable after 30 days of operation, and they achieved …" · T=22°C, pH(an)=7.47, substrate=synthetic wastewater, HRT=18.4hModelable
Nitrogen Removal82.4%90%
extracted
"The average removal rate of TN (82.39%) and NO3−-N (52.16%) in Device A were hig…" · T=22°C, pH(an)=7.47, substrate=synthetic wastewater, HRT=18.4hModelable
Chemical Oxygen Demand (COD) Removal98.4%90%
extracted
"Device A and Device B were stable after 30 days of operation, and they achieved …" · T=22°C, pH(an)=7.34, substrate=synthetic wastewater, HRT=18.4hModelable
Nitrogen Removal79.3%90%
extracted
"The average removal rate of TN (82.39%) and NO3−-N (52.16%) in Device A were hig…" · T=22°C, pH(an)=7.34, substrate=synthetic wastewater, HRT=18.4hModelable
Dissolved Oxygen4.83mg/L90%
extracted
"The effluent DO in both Device A (5.31 mg/L) and Device B (4.83 mg/L) were higher …" · T=22°C, pH(an)=7.34, substrate=synthetic wastewater, HRT=18.4hModelable

Methodology

What was the system and how was it run

Methodology

Methodology

Two identical TFCW-MFCs (50 cm diameter, 80 cm height) with granular activated carbon anode and stainless-steel mesh cathode were operated at C/N ratios of 10:1 and 5:1 for 90 days. Tidal flow cycles consisted of 5 h flooding, 12 min draining, 4 h resting, and 2 h recirculation (total HRT 18.4 h). Wastewater parameters (COD, NH₄⁺-N, NO₂⁻-N, NO₃⁻-N, TN, DO, pH) were measured every 2 days. Voltage was logged continuously. Microbial samples were collected from four layers (cathode, upper, anode, bottom) on days 30 and 90, and analyzed by high-throughput 16S rRNA sequencing for AOA, AOB, NOB, and general community composition. Alpha diversity (Chao, Shannon) and community structure (PCoA, RDA) were analyzed using QIIME and Canoco.

System configuration

FieldValue
reactor typeMES
chamber config2-chamber

Operating conditions

2 runs extracted
RunT°CpHanpHcatSubstrate[S]mg/LHRThModeR_extΩV_appVInoculum
v2-0639d6daf9614b8b227.47—synthetic wastewater—18.4—1000——
v2-77e9a0ce2b2cb442227.34—synthetic wastewater—18.4—1000——

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

AI confidence

78%

Model self-reported confidence

Mean parameter confidence

90%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

07

Source PDF

The paper as published.

loading 3D model…

Representative model, generic MFC

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

MFC
System
25.8milliwatts per square metre
Best result · Power density
best of 2
21
Extracted values
2020
Year

Keywords

  • Nitrobacter
  • Nitrosomonas
  • Nitrosomonas europaea
  • Microbial fuel cell
  • Microbial population biology
  • Nitrification

Cite

Longmian Wang, Qingqing Pang, Fuquan Peng et al. (2020). Response Characteristics of Nitrifying Bacteria and Archaea Community Involved in Nitrogen Removal and Bioelectricity Generation in Integrated Tidal Flow Constructed Wetland-Microbial Fuel Cell. Frontiers in Microbiology. https://doi.org/10.3389/fmicb.2020.01385

PubMed
32655535

Open in lab for full controls, parameter editing, and template overlays.