Research

Paper · MES

Accelerated H2 Evolution during Microbial Electrosynthesis with Sporomusa ovata

01

Summary

What the paper reports, in its own words.

3D Interactive Model

Abstract

Microbial electrosynthesis (MES) is a process where bacteria acquire electrons from a cathode to convert CO2 into multicarbon compounds or methane. In MES with Sporomusa ovata as the microbial catalyst, cathode potential has often been used as a benchmark to determine whether electron uptake is hydrogen-dependent. In this study, H2 was detected by a microsensor in proximity to the cathode. With a sterile fresh medium, H2 was produced at a potential of −700 mV versus Ag/AgCl, whereas H2 was detected at −500 mV versus Ag/AgCl with cell-free spent medium from a S. ovata culture. Furthermore, H2 evolution rates were increased with potentials lower than −500 mV in the presence of cell-free spent medium in the cathode chamber. Nickel and cobalt were detected at the cathode surface after exposure to the spent medium, suggesting a possible participation of these catalytic metals in the observed faster hydrogen evolution. The results presented here show that S. ovata-induced alterations of the cathodic electrolytes of a MES reactor reduced the electrical energy required for hydrogen evolution. These observations also indicated that, even at higher cathode potentials, at least a part of the electrons coming from the electrode are transferred to S. ovata via H2 during MES.

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 41 extracted values

Select a citation to see the quote, page and confidence behind a value.

1 of 41 extracted rows modelable

  • 26 not canonicalised (no canonical slug)
  • 1 no SI value
  • 13 verifier rejected the value
ParameterValueUnitConfidenceSourceNotesModelable
Current Density-398mA m⁻²90%
extracted
"Table 3. Current Density (mA m−2) at −900 mV: −398 ± 90" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: verifier rejected the value
Current Density-16.3mA m⁻²90%
extracted
"Current Density (mA m−2) at −850 mV: −16.3 ± 1.7" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: verifier rejected the value
Current Density-289mA m⁻²90%
extracted
"Table 3. Current Density (mA m−2) at −800 mV: −289 ± 38" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: verifier rejected the value
Current Density-14.9mA m⁻²90%
extracted
"Current Density (mA m−2) at −800 mV: −14.9 ± 1.8" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: verifier rejected the value
Current Density-254mA m⁻²90%
extracted
"Table 3. Current Density (mA m−2) at −700 mV: −254 ± 60" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: verifier rejected the value
Current Density-179mA m⁻²90%
extracted
"Table 3. Current Density (mA m−2) at −500 mV: −179 ± 42" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: verifier rejected the value
Coulombic efficiency75%90%
extracted
"and the coulombic efficiency was 75 ± 3%" · T=25°C, pH(an)=6.8, substrate=CO2Modelable
Current Density-276mA m⁻²90%
extracted
"Table 3. Current Density (mA m−2) at −750 mV: −276 ± 51" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: verifier rejected the value
Current Density-19.8mA m⁻²90%
extracted
"Current Density (mA m−2) at −900 mV: −19.8 ± 2.1" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: verifier rejected the value
Current Density-12.8mA m⁻²90%
extracted
"Current Density (mA m−2) at −700 mV: −12.8 ± 1.0" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: verifier rejected the value
Current Density-317mA m⁻²90%
extracted
"Table 2. Current Density (mA m−2) at −900 mV: −317 ± 32" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: verifier rejected the value
Current Density-320mA m⁻²90%
extracted
"Table 3. Current Density (mA m−2) at −850 mV: −320 ± 86" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: verifier rejected the value
Current Density-225mA m⁻²90%
extracted
"Table 3. Current Density (mA m−2) at −600 mV: −225 ± 47" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: verifier rejected the value
Current Density-13.7mA m⁻²90%
extracted
"Current Density (mA m−2) at −750 mV: −13.7 ± 1.2" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: verifier rejected the value
H₂ Evolution Rates0.048µM min⁻¹90%
extracted
"Table 1. H2 Evolution Rates (µM min−1) at −700 mV: 0.048 ± 0.007" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: not canonicalised (no canonical slug)
Electrons Recovery in H₂80%90%
extracted
"Table 3. Electrons Recovery in H2 (%) at −750 mV: 80 ± 3.2" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: not canonicalised (no canonical slug)
Electrons Recovery in H₂75%90%
extracted
"Table 3. Electrons Recovery in H2 (%) at −700 mV: 75 ± 3.0" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: not canonicalised (no canonical slug)
Electrons Recovery in H₂87%90%
extracted
"Electrons Recovery in H2 (%) at −900 mV: 87 ± 1.8" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: not canonicalised (no canonical slug)
Electrons Recovery in H₂87%90%
extracted
"Table 3. Electrons Recovery in H2 (%) at −900 mV: 87 ± 8.4" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: not canonicalised (no canonical slug)
Electrons Recovery in H₂79%90%
extracted
"Electrons Recovery in H2 (%) at −750 mV: 79 ± 9.0" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: not canonicalised (no canonical slug)
H₂ Evolution Rates0.11µM min⁻¹90%
extracted
"At −900 mV, 0.11 ± 0.02 µM min−1 (n = 3) of H2 accumulated" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: not canonicalised (no canonical slug)
H₂ Evolution Rates0.73µM min⁻¹90%
extracted
"Table 3. H2 Evolution Rates (µM min−1) at −500 mV: 0.73 ± 0.08" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: not canonicalised (no canonical slug)
H₂ Evolution Rates0.84µM min⁻¹90%
extracted
"Table 3. H2 Evolution Rates (µM min−1) at −600 mV: 0.84 ± 0.10" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: not canonicalised (no canonical slug)
Electrons Recovery in H₂74%90%
extracted
"Table 3. Electrons Recovery in H2 (%) at −600 mV: 74 ± 5.9" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: not canonicalised (no canonical slug)
H₂ Evolution Rates0.073µM min⁻¹90%
extracted
"Table 1. H2 Evolution Rates (µM min−1) at −850 mV: 0.073 ± 0.010" · T=25°C, pH(an)=6.8, substrate=CO2Excluded: not canonicalised (no canonical slug)
Showing 25 of 41

Methodology

What was the system and how was it run

Operating conditions

1 run extracted
RunT°CpHanpHcatSubstrate[S]mg/LHRThModeR_extΩV_appVInoculum
v2-7f77ac38d1c9a1fe256.8—CO2——————

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

AI confidence

60%

Model self-reported confidence

Mean parameter confidence

90%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

07

Source PDF

The paper as published.

loading 3D model…

Representative model, generic microbial electrochemical system

Representative microbial electrochemical system — matched on the paper’s system type only, not its reactor or geometry.

MES
System
-0.01amperes per square metre
Best result · Current density
best of 13
41
Extracted values
2019
Year

In this record

Organisms, parameters and materials this paper reports. Each links to its page.

Organisms · 1

Keywords

  • Electrosynthesis

Cite

Pier‐Luc Tremblay, Neda Faraghiparapari, Tian Zhang (2019). Accelerated H2 Evolution during Microbial Electrosynthesis with Sporomusa ovata. Catalysts. https://doi.org/10.3390/catal9020166

Journal
Catalysts

Open in lab for full controls, parameter editing, and template overlays.

Open in lab