Study of The Effect of pH on The Performance of Microbial Fuel Cell for Generation of Bioelectricity
Md. Abdul Halim, Md. Owaleur Rahman, Md. Ibrahim, Rituparna Kundu +1
AI summary
70% confidenceThe study investigates the effect of pH on the performance of a microbial fuel cell (MFC) using different types of wastewater as electrolytes, and finds that the optimal pH for maximum output is 8.
Generated by MESSAI extraction pipeline · review against source PDF
Reported parameters
No extracted parameters yet — request AI extraction to compare this paper against literature distributions.
Open in lab for full controls, parameter editing, and template overlays.
Open in lab →What they did
- System
- MFC
- Substrate
- real wastewater
What worked
No outcome metrics extracted yet.
Abstract
Abstract Background: Day by day microbial fuel cell (MFC) technology is becoming a thought-provoking topic to the researcher because for its simultaneous utilization e.g. electricity production and wastewater treatment. Since wastewater is an important source of electrolyte for MFC, the key tenacity of this study was to investigate the outcome of pH happening various (Municipal, Bhairab river and Hospital) wastewaters used as electrolyte in dual chamber MFC. Findings: The lab-scale experiment was conducted in batch mode, where zinc plate (0.0027 m 2 ) as anode and copper plate (0.0027 m 2 ) as cathode. In this study a single electrolyte (any one of earlier mentioned three electrolytes) was used in five dual-chambers MFC where the pH of the electrolyte was 6, 7, 8, 9 and 10. The MFC was worked on a temperature ranged from 27°C to 34°C. Maximum outputs were found in terms of current density (1288.9 mAm - 2 ), voltage (1132 mV) and power density (1459.02 wmw - 2 ) were obtained at pH 8 by using Bhairab river water as an electrolyte in MFC chamber. A substantial amount of COD removal (94%) was also achieved in the same MFC chamber at the same pH (i.e. pH 8). However, the optimum operating pH for MFC containing municipal wastewater and hospital wastewater was found to be 8 and 9, respectively. Conclusion: The results suggest that various wastewaters may act as feasible feedstocks for bioelectricity generation in MFC. The results also show that COD can be removed from wastewater that suggest a treatment possibility of wastewater.
Key findings
- Maximum current density (1288.9 mAm-2) was obtained at pH 8 using Bhairab river water as electrolyte.
- Maximum voltage (1132 mV) and power density (1459.02 wmw-2) were also obtained at pH 8.
- The study suggests that pH 8 is the optimal pH for MFC performance using wastewater as electrolyte.
Keywords
Identifiers
- Journal
- Research Square
- Year
- 2021