Lane Gilchrist · Reaction-diffusion · draft 13 Nov 2026
Which reaction-diffusion parameters does the MES literature report?
A spatial reaction-diffusion model of an electrode biofilm needs transport, structure and kinetic parameters measured on the same system. This page counts how often the literature on microbial electrochemical systems (MES) reports each one next to a measured outcome, names the gaps, and proposes what to build.
ProposalNothing is fitted. Every number is a paper-level count from MESSAI’s public parameter export (committed Oct 27, 2026): a lower bound, not an effect estimate.
The question
Can a reaction-diffusion model of an electrode biofilm be parameterised from the literature?
Not yet. Of 11 parameters such a model needs, the most reported one appears in 27 of 7,885 papers, and the diffusion coefficient has no entry of its own.
The export holds 196,522 extracted values from 7,885 papers with a DOI.
Parameter map
Eleven parameters against three outcomes. Select a cell to see what the parameter does in a model, how often it is reported and why it is a gap.
no paper1–2 papers3–9 papers10 or more
Each cell: papers that report the parameter and that outcome. Select a cell for the detail.
Parameter · papers
Current density
Power density
Coulombic efficiency
Diffusion coefficient *9
Mass-transfer coefficient3
Tortuosity *0
Biofilm thickness14
Biofilm porosity15
Biofilm density12
Biofilm conductivity2
Average pore size12
Specific surface area27
Half-saturation constant6
Specific growth rate15
* No canonical parameter exists; matched by reported name. “Usable” counts values with a canonical parameter, an SI value in a plausible range and a passed check. Across the whole export: current density 799 papers, power density 1,316, coulombic efficiency 755.
Three gaps
Diffusion has no entry
No canonical parameter exists for a diffusion coefficient. Matching by reported name finds 52 values in 9 papers, with species and medium unrecorded and none usable for modeling. Tortuosity: 0 values.
Conduction is nearly absent
Biofilm conductivity is reported by 2 papers (5 values, 0 usable for modeling).
Evidence split across spellings
3 of the 11 parameters are stored under two spellings, so a query on one sees part of the evidence. The counts on this page merge them.
Open puzzles
Questions the export cannot answer today, with what it holds and what would settle each.
1
Is an anode biofilm limited by substrate diffusion or by electron conduction?
The answer needs three numbers from one biofilm: thickness, the substrate’s diffusion coefficient inside it, and conductivity. Thickness is reported by 14 papers, conductivity by 2, a diffusion coefficient by 9, a mass-transfer coefficient by 3. Papers reporting all three: 1.
Would settle it: the three measured on one biofilm, then the ratio of reaction rate to diffusion rate (Thiele modulus).
How far does a secreted flavin carry electrons inside a pore?
Shewanella oneidensis secretes flavins that carry electrons to the electrode (Marsili et al. 2008). The reach depends on pore geometry, the flavin’s diffusion coefficient and the transfer rates at cell and electrode. The export has 38 values naming a flavin, from 10 papers, and no flavin diffusion coefficient.
Would settle it: a particle-based simulation (MCell) in a measured pore geometry, compared with a continuum model using the same parameters.
Do the pores an electrode reports leave room for its biofilm?
Pore size is reported by 12 papers and biofilm thickness by 14. Papers reporting both: 2. The pore explorer computes the wall area a cell can reach for a chosen smallest pore, but its scans are of a carbon black / PTFE electrode layer and platinum-catalyst particles, not of an MES anode.
Would settle it: an open tomogram of carbon felt or carbon cloth, with biofilm thickness measured on the same material.
The cell the biofilm sits in, and three anode materials with the pore-scale numbers a model needs.
Where the biofilm sits
Microbial fuel cell (MFC)
A biofilm on a graphite-brush anode oxidises the substrate; the electrons run through an external load to an air cathode. Substrate diffuses in from the liquid and electrons travel out through the biofilm, so both lengths are set by its thickness. Example geometry. Drag to orbit.
Microbial fuel cell (MFC)
Anode microstructure: the electrode side of the model
Porosity and permeability set how liquid moves through the electrode; tortuosity sets effective diffusion; specific surface sets how much area a biofilm can colonise. The values below are textbook ranges, shown to mark what a measured scan would replace.
Example literature ranges (example data): not measured, not simulated
Carbon felt
literature range
Property
Value · Range
Porosity
0.930.9–0.96
Tortuosity
1.81.4–2.6
Specific surface
30,000m²/m³square metres per cubic metre10,000–100,000
Permeability
3.00e-10m²square metres1.00e-10–1.00e-9
Thickness
5mmmillimetres4–6
Manufacturer datasheet range (SGL / Sigracell felt series); specific surface is a geometric estimate from fibre diameter; illustrative
Carbon cloth
literature range
Property
Value · Range
Porosity
0.80.75–0.85
Tortuosity
1.51.2–2
Specific surface
100,000m²/m³square metres per cubic metre50,000–200,000
Permeability
2.00e-11m²square metres1.00e-11–1.00e-10
Thickness
350µmmicrometres300–500
Typical woven PAN carbon cloth range (0.3 to 0.5 mm); permeability is an order-of-magnitude estimate between paper and felt; illustrative
Graphite fibre brush
literature range
Property
Value · Range
Porosity
0.960.95–0.98
Tortuosity
1.51.2–2
Specific surface
16,000m²/m³square metres per cubic metre5,000–50,000
Permeability
1.00e-8m²square metres1.00e-9–1.00e-7
Thickness
30mmmillimetres20–100
Typical graphite fibre brush range; specific surface quoted per brush volume; thickness is the brush envelope diameter and varies widely by design; illustrative
Measured pore geometry in place of textbook values: the pore explorer.
Measured pore geometry
Electrode tomograms, coloured by local pore diameter. Drag to orbit; pick a scan to change scale.
Carbon black / PTFE electrode layer
Vulcan XC / PTFE · Pore network
Loading the scan…
These are analogue scans, not a microbial-electrochemical anode: a carbon black / PTFE electrode layer and platinum-catalyst particles on carbon. The library holds no scan of a felt, cloth or brush anode and none of a biofilm.
Of the map’s parameters these steps record one: biofilm thickness, by confocal z-stack in the imaging step. No step in the protocol graph records a diffusion coefficient or biofilm conductivity.
A diffusion-coefficient entry with species and medium
Proposed
Add a canonical diffusion coefficient that records the diffusing species and the medium (water, biofilm, membrane), and merge the 3 parameters stored under two spellings.
2
A targeted extraction
Proposed
Re-read the 9 papers that name a diffusion coefficient and the 10 that name a flavin. Store each value with its DOI and the sentence it came from.
3
A Thiele modulus in the pore explorer
Proposed
The Electron transfer tab of the pore explorer reports penetration depth and supply limit. Add the Thiele modulus from the same inputs, so the page states whether diffusion or reaction limits.
4
Scan geometry for MCell
Proposed
Export each scan as a surface mesh that CellBlender imports, with a parameter file listing every value and its source.
5
Two protocol steps
Proposed
Add steps to the protocol graph for measuring biofilm conductivity and an effective diffusion coefficient, each with method, equipment and references.
Live pages
What already exists, in the order to open it.
Pore explorer — Four measured tomograms, from a 42 µm electrode layer to a 22 nm catalyst support, cut open in 3D. The Electron transfer tab links pore geometry to current.
Geobacter sulfurreducens PCA — Growth and electron-transfer kinetics. Every value carries its paper, DOI, source sentence and check result.