AI summary

75% confidence

A novel biosensor for continuous Cr(VI) monitoring using a single-chamber microbial fuel cell (MFC) was developed, demonstrating robust performance and characteristics.

Generated by MESSAI extraction pipeline · review against source PDF

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

4 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC

What worked

No outcome metrics extracted yet.

Abstract

Hexavalent chromium (Cr(VI)) is a high-priority environmental pollutant due to its strong oxidizing properties, which cause DNA damage and other severe health effects. Conventional detection methods are often costly and lack real-time monitoring capabilities, creating a strong demand for cost-effective, real-time biosensors that meet industrial requirements. In this study, we developed a novel biosensor for continuous Cr(VI) monitoring using a single-chamber microbial fuel cell (MFC). The biological element is an engineered Escherichia coli strain ( ChrA-ChrB-E. coli ), constructed by introducing Cr(VI)-resistant ( ChrA ) and Cr(VI)-reducing ( ChrB ) genes. The presence of Cr(VI) affects bacterial metabolism and electron transfer within the MFC, generating a measurable signal proportional to the contaminant's concentration. The biosensor demonstrated robust performance and characteristics. The recombinant strain retained functional activity after 450 days of storage at -20 °C. The system exhibited high sensitivity and excellent linearity (R 2 ≥ 0.999) across a broad Cr(VI) concentration range of 0.015-200 mg/L. During continuous monitoring of chrome tanning and electroplating wastewater, measurements deviated by less than 2.33% from the standard diphenylcarbazide (DPC) method; electroplating deviation was further reduced to -0.69% with EDTA pretreatment. In fishery water, the deviation was higher (-7.12%) due to dissolved oxygen (DO) interference but was reduced to -0.75% after mechanical stirring to remove DO. The biofilm bacterial community remained highly stable over six months in both wastewater types, with the inoculated ChrA-ChrB-E. coli strain maintaining dominance (>99.6%). These results substantiate the feasibility of using this biosensor for continuous, online, real-time detection of Cr(VI) in actual wastewater environments.

Keywords

Hexavalent chromiumBiosensorMicrobial fuel cellWastewaterPulp and paper industryBioreactor

Identifiers

PubMed
41744748
Journal
Biosensors
Year
2026