Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

No values extracted from this paper yet.

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC

What worked

No outcome metrics extracted yet.

Abstract

The usage time of air-cathode microbial fuel cells (MFCs) is significantly influenced by the moisture content within the proton exchange membrane (PEM). Therefore, enhancing the water retention capability of the PEM by applying a hydrophobic polymer coating to its surface has extended the PEM's usage time by three times and increased MFCs' operational duration by 66%. Moreover, the hydrophobic nature of the polymer coating reduces contamination on the PEM and prevents anode liquid from permeating into the air cathode. Towards the end of MFC operation, the internal resistance of the MFC is reduced by 45%. The polymer coating effectively maintained the oxygen reduction reaction activity in the cathode. The polymer coating's ability to restrict oxygen transmembrane diffusion is demonstrated by experimental data showing a significant decrease in oxygen diffusion coefficient due to its presence. The degradation efficiency of the chemical oxygen demand from 16% to 35% increased by a factor of one.

Keywords

Microbial fuel cellCathodeCoatingProton exchange membrane fuel cellPolymerChemical engineering

Identifiers

PubMed
38541442
Journal
Materials
Year
2024