Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

No values extracted from this paper yet.

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC

What worked

No outcome metrics extracted yet.

Abstract

The constructed magnetic MFCs obtained better performance compared with the non-magnetic MFC, in terms of voltage production, power density, and coulombic efficiency. The relative abundance of Geobacter spp. (one kind of exoelectrogen) was much higher in the magnetic MFCs. The optimal static magnetic field intensity for enriching exoelectrogens is around 80 mT. It is likely that the decrease of internal resistance, enrichment in exoelectrogens, and the syntrophic interactions between exoelectrogens and methanogens result in the enhanced performance of magnetic MFCs. This study provides a magnetic method for the enrichment of exoelectrogens, which can be extensively applied in bioelectrochemical systems.

Keywords

Microbial fuel cellElectron transferBacteriaExtracellularAnodeExtracellular vesicles

Identifiers

PubMed
31164924
Journal
Biotechnology for Biofuels
Year
2019