AI summary

70% confidence

A three-stage single-chambered microbial fuel cell (SCMFC) biosensor was developed for continuous chromium (VI) measurement, showing a negative linear relationship between Cr(VI) concentration and voltage output.

Generated by MESSAI extraction pipeline · review against source PDF

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

163 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC
Substrate
real wastewater

What worked

No outcome metrics extracted yet.

Abstract

Chromium (VI) [Cr(VI)] compounds display high toxic, mutagenic, and carcinogenic potential. Biological analysis techniques (e.g., such as enzyme-based or cell-based sensors) have been developed to measure Cr(VI); however, these biological elements are sensitive to the environment, limited to measuring trace Cr(VI), and require deployment offsite. In this study, a three-stage single-chambered microbial fuel cell (SCMFC) biosensor inoculated with Exiguobacterium aestuarii YC211 was developed for in situ, real-time, and continuous Cr(VI) measurement. A negative linear relationship was observed between the Cr(VI) concentration (5–30 mg/L) and the voltage output using an SCMFC at 2-min liquid retention time. The theoretical Cr(VI) measurement range of the system could be extended to 5–90 mg/L by connecting three separate SCMFCs in series. The three-stage SCMFC biosensor could accurately measure Cr(VI) concentrations in actual tannery wastewater with low deviations (<7%). After treating the wastewater with the SCMFC, the original inoculated E. aestuarii remained dominant (>92.5%), according to the next-generation sequencing analysis. The stable bacterial community present in the SCMFC favored the reliable performance of the SCMFC biosensor. Thus, the three-stage SCMFC biosensor has potential as an early warning device with wide dynamic range for in situ, real-time, and continuous Cr(VI) measurement of tannery wastewater.

Key findings

  • A linear relationship was observed between Cr(VI) concentration (5–30 mg/L) and voltage output using an SCMFC at 2-min liquid retention time.
  • The theoretical Cr(VI) measurement range of the system could be extended to 5–90 mg/L by connecting three separate SCMFCs in series.
  • The SCMFC biosensor could accurately measure Cr(VI) concentrations in actual tannery wastewater with low deviations (<7%).

Keywords

ChromiumBiosensorStage (stratigraphy)Microbial fuel cellMicrobiologySingle stage

Identifiers

Journal
Sensors
Year
2019