AI summary

70% confidence

This paper investigates the poisoning effects of CO and CO2 on a PBI-based HT-PEM fuel cell using EIS, showing that CO poisoning affects all losses monitored and intermediate frequency resistances increase with contamination.

Generated by MESSAI extraction pipeline · review against source PDF

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

3 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC

What worked

No outcome metrics extracted yet.

Abstract

This paper presents test results regarding the poisoning effects of CO and CO2 on H3PO4/Polybenzimidazole (PBI) membrane based high temperature proton exchange membrane fuel cell (HT-PEMFC). Electrochemical impedance spectroscopy (EIS), which is a non intrusive diagnostic tool for electrochemical systems, has been used to investigate these effects. A single cell test setup consisting of an electrically heated single cell assembly with a PEMEAS CELTEC P membrane electrode assembly (MEA) of an active area of 45cm² and mass flow controllers for Air, H2, CO and CO2 was constructed in the laboratory. All operational parameters as well as data acquisition are controlled by two LabView programs, running on two separate computers. The impedance spectrum of the fuel cell is recorded at different operating points and then an Equivalent Circuit (EC), proposed for modelling the cell impedance, is fitted to the spectrum in order to analyze and quantify the impact of the individual factors on HT-PEMFC performance. Results showed that CO poisoning has an effect on all the losses monitored. Intermediate frequency resistances showed higher increase with increasing contamination and decreasing temperature than high frequency resistances, which is attributable to the adsorption of CO on Pt catalyst.

Key findings

  • CO poisoning has a significant impact on HT-PEMFC performance
  • Intermediate frequency resistances increase with increasing CO contamination
  • CO2 has a lesser effect on HT-PEMFC performance compared to CO

Keywords

Proton exchange membrane fuel cellDielectric spectroscopyElectrical impedanceCO poisoningElectrodeElectrochemistry

Identifiers

Journal
ASME 2010 8th International Fuel Cell Science, Engineering and Technology Conference: Volume 1
Year