Microbial Electrochemically Assisted Treatment Wetlands: Current Flow Density as a Performance Indicator in Real-Scale Systems in Mediterranean and Northern European Locations
Lorena Peñacoba-Antona, Carlos Andres Ramirez-Vargas, Colin Wardman, Alessandro A. Carmona-Martinez +4
AI summary
70% confidenceThis study investigates the performance of Microbial Electrochemically Assisted Treatment Wetlands (METlands) in real-scale systems, focusing on the correlation between current flow density and pollutant removal efficiency.
Generated by MESSAI extraction pipeline · review against source PDF
No 3D model is mapped to this paper yet. Parameter ranges above still place reported values on the literature distribution.
Abstract
A METland is an innovative treatment wetland (TW) that relies on the stimulation of electroactive bacteria (EAB) to enhance the degradation of pollutants. The METland is designed in a short-circuit mode (in the absence of an external circuit) using an electroconductive bed capable of accepting electrons from the microbial metabolism of pollutants. Although METlands are proven to be highly efficient in removing organic pollutants, the study of in situ EAB activity in full-scale systems is a challenge due to the absence of a two-electrode configuration. For the first time, four independent full-scale METland systems were tested for the removal of organic pollutants and nutrients, establishing a correlation with the electroactive response generated by the presence of EAB. The removal efficiency of the systems was enhanced by plants and mixed oxic–anoxic conditions, with an average removal of 56 g of chemical oxygen demand (COD) m bed material –3 day –1 and 2 g of total nitrogen (TN) m bed material –3 day –1 for Ørby 2 (partially saturated system). The estimated electron current density ( J ) provides evidence of the presence of EAB and its relationship with the removal of organic matter. The tested METland systems reached the max. values of 188.14 mA m –2 (planted system; IMDEA 1), 223.84 mA m –2 (non-planted system; IMDEA 2), 125.96 mA m –2 (full saturated system; Ørby 1), and 123.01 mA m –2 (partially saturated system; Ørby 2). These electron flow values were remarkable for systems that were not designed for energy harvesting and unequivocally show how electrons circulate even in the absence of a two-electrode system. The relation between organic load rate (OLR) at the inlet and coulombic efficiency (CE; %) showed a decreasing trend, with values ranging from 8.8 to 53% (OLR from 2.0 to 16.4 g COD m –2 day –1 ) for IMDEA systems and from 0.8 to 2.5% (OLR from 41.9 to 45.6 g COD m –2 day –1 ) for Ørby systems. This pattern denotes that the treatment of complex mixtures such as real wastewater with high and variable OLR should not necessarily result in high CE values. METland technology was validated as an innovative and efficient solution for treating wastewater for decentralized locations.
Key findings
- Four independent full-scale METland systems were tested for organic pollutant and nutrient removal, with an average removal of 56 g COD m⁻³ day⁻¹ and 2 g TN m⁻³ day⁻¹.
- The removal efficiency was enhanced by plants and mixed oxic-anoxic conditions.
- A correlation was established between the electroactive response generated by electroactive bacteria (EAB) and pollutant removal efficiency.
Keywords
Identifiers
- Journal
- Frontiers in Microbiology
- Year
- 2022