AI summary

70% confidence

Experimental study on PEM fuel cell cold start performance, identifying optimal operational parameters for self-start-up at -5°C in 30 minutes.

Generated by MESSAI extraction pipeline · review against source PDF

Generic MECRepresentative model
Click to animate flow
loading 3D model…

Representative MEC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

3 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MEC

What worked

No outcome metrics extracted yet.

Abstract

Abstract In this paper, experimental investigations on the influence of operational parameters on PEM fuel cell cold start are presented. The effect of current density, stack impedance at 1 kHz prior to start, as well as gas flow rate, gas pressure, coolant flow rate and surrounding subfreezing temperature are studied. The experimental apparatus is briefly described. It includes a main unit at room temperature and a smaller separate unit in a climatic chamber. Low current density, high impedance prior to start, moderate subfreezing temperature (–5 °C), high gas flow rate, low gas pressure and low coolant flow rate are found to have a positive impact on the cold start performance. Combining these parameters, self start‐up of the fuel cell without additional energy is achieved at –5 °C in 30 min. The whole set of observations leads to the following hypotheses on freeze mechanism: in the first phase, dry membranes and low current lead to a transient phase of membrane humidification. Then, in the second phase, ice clogging of the active layers occurs. In the third phase, a variable quantity of the produced water reaches the gas diffusion layers and channels.

Key findings

  • Low current density improves cold start performance.
  • High impedance prior to start has a positive impact on cold start performance.
  • Combining optimal parameters enables self-start-up without additional energy.

Keywords

Cold start (automotive)CoolantStack (abstract data type)Volumetric flow rateCurrent (fluid)Clogging

Identifiers

Journal
Fuel Cells
Year
2008