AI summary

70% confidence

A large-scale microbial fuel cell system successfully treated swine wastewater for over 200 days, achieving up to 65% COD removal and a maximum treatment rate of 5.0 kg COD/m³.day.

Generated by MESSAI extraction pipeline · review against source PDF

Literature priors

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Distribution

Reported parameters

The author’s reported value (▼) sits on top of the literature distribution from MESS-Parameters. Values outside the band are flagged as outliers.

Coulombic efficiency5%

3 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC

What worked

No outcome metrics extracted yet.

Abstract

Abstract Microbial fuel cells (MFCs) have long held the promise of being a cost‐effective technology for the energy‐neutral treatment of wastewater. However, successful pilot‐scale demonstrations for this technology are still limited to very few. Here, we present a large‐scale MFC system, composed of 12 MFCs with a total volume of 110 L, successfully treating swine wastewater at a small educational farm. The system was operated for over 200 days in continuous mode with hydraulic residence time of 4 hr. Very stable electrochemical and waste treatment performance was observed with up to 65% of chemical oxygen demand (COD) removed and a maximum treatment rate of 5.0 kg COD/m 3 .day. Robust microbial enrichment was performed and adapted to metabolize and transform a diversity of compounds present. The Net Energy Recovery (NER = 0.11 kWhr/kg COD) is not only competitive with conventional cogeneration processes, but is in fact sufficient to sustain the operational energy requirements of the system. Practitioner points This study demonstrates the design and operation of a large‐scale microbial fuel cells (MFC) system for continuous treatment of swine wastewater. The system achieved a high chemical oxygen demand removal rate within a short hydraulic residence time. This study moves one‐step closer to applying MFC technology for real wastewater treatment.

Key findings

  • A 12-MFC system with a total volume of 110 L was operated in continuous mode with a hydraulic residence time of 4 hours.
  • The system achieved stable electrochemical and waste treatment performance, with a Net Energy Recovery of 0.11 kWhr/kg COD.
  • The system was able to sustain its operational energy requirements through energy recovery.

Keywords

Waste managementMicrobial fuel cellWaste treatmentScale (ratio)Environmental engineering

Identifiers

Journal
Water Environment Research
Year
2019