AI summary

70% confidence

A constructed wetland-microbial fuel cell (CW-MFC) system was developed to treat hexavalent chromium (Cr(VI)) wastewater, achieving higher removal efficiency and electricity generation compared to a constructed wetland system.

Generated by MESSAI extraction pipeline · review against source PDF

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

54 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC

What worked

No outcome metrics extracted yet.

Abstract

Cr(VI) is toxic to the human body and environment. As a suitable wastewater treatment with low energy requirement technology, constructed wetland-microbial fuel cells (CW-MFCs) can treat Cr(VI) wastewater while generating electricity. In this study, CW-MFC and constructed wetland systems were developed to purify Cr(VI) wastewater. The removal mechanism of Cr(VI) was examined by electron paramagnetic resonance (EPR), X-ray photoelectron spectroscopy (XPS), and Fourier transform infrared spectroscopy. The results demonstrated that the average pollutant removal efficiency of the CW-MFC system is 2.99–8.13% higher than that of the constructed wetland system, and the maximum power density is 505.61 mW m −2 . Moreover, the XPS and EPR analyses demonstrated that Cr in substrates and Leersia hexandra Swartz primarily is in the form of Cr(III). Moreover, in plants and substrates, the Cr(III) content of the CW-MFC system was higher than that of the control, and the bioconcentration and translocation factors were 0.23 and 0.05 higher than those in the control group, respectively. Therefore, the CW-MFC system can efficiently remove Cr(VI) and promote the accumulation and transport of Cr. Microbial community diversity in the CW-MFC was significantly higher than CW. The abundance of electrogenic bacteria Geobacter and metal dissimilatory reducing bacteria Acinetobacter in CW-MFC is higher than that in CW. To summarize, the study results provide a theoretical basis for the mechanism study of Cr(VI) wastewater treatment using CW-MFC systems.

Key findings

  • The CW-MFC system achieved an average pollutant removal efficiency 2.99-8.13% higher than the constructed wetland system.
  • The maximum power density of the CW-MFC system was 505.61 mW m⁻².
  • The Cr(III) content in plants and substrates of the CW-MFC system was higher than the control group, with bioconcentration and translocation factors 0.23 and 0.05 higher, respectively.

Keywords

Microbial fuel cellWastewaterConstructed wetlandHexavalent chromiumSewage treatmentEnvironmental chemistry

Identifiers

Journal
Frontiers in Environmental Science
Year
2022