Simultaneous heavy metal reduction and voltage generation with synergy membrane-less microbial fuel cell
Kam-Khong Chan, Wei-Eng Thung, Soon-An Ong, Li-Ngee Ho +2
AI summary
70% confidenceA synergy membrane-less microbial fuel cell (UFML-MFC) was fabricated to study the feasibility of heavy metal reduction and voltage generation, with Cu (II) as the electron acceptor. The performance of the UFML-MFC deteriorated with increased initial concentration of Cu (II), resulting in decreased voltage generation, COD reduction, and Cu (II) reduction efficiency. The results show that the UFML-MFC can be used for heavy metal reduction, but its performance is affected by the initial concentration of Cu (II).
Generated by MESSAI extraction pipeline · review against source PDF
Literature priors
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
Reported parameters
The author’s reported value (▼) sits on top of the literature distribution from MESS-Parameters. Values outside the band are flagged as outliers.
10 extracted values
View extracted valuesOpen in lab for full controls, parameter editing, and template overlays.
Open in lab →What they did
- System
- MFC
What worked
No outcome metrics extracted yet.
Abstract
Abstract Metal contaminated wastewater effluent from industries has caused several environmental problems and public health due to its toxicity. Conventional heavy metal reduction processes are neither economical nor environmentally friendly. A synergy economical single chamber up-flow membrane-less microbial fuel cell (UFML-MFC) was fabricated to study the feasibility of heavy metal reduction and voltage generation. Cu (II) was used as electron acceptor to explore the mechanism of metal treatment in UFML-MFC. The performances of the UFML-MFC were investigated with 0 mg/L, 5 mg/L and 10 mg/L concentration of Cu (II) in terms of voltage output, chemical oxygen demand (COD) reduction and Cu (II) reduction efficiency and electrode spacing distance. UFML-MFC used carbon felt as anode and cathode material where anode region was filled with 0.2 cm of gravels at anode region. Overall performance deteriorated with increased initial concentration of Cu (II). Voltage generation decreased from 71 mV to 11.1 mV. COD reduction decreased from 56% to 36%. Moreover, the Cu (II) reduction efficiency was reduced from 87.56% to 36.98%. These results showed that the increased concentration of the Cu (II) could potentially reduce the microbial activities. However, UFML-MFC showed that the shorter distance of electrode spacing (anode and cathode) could enhanced the voltage output. These results showed the great ability of integrating UFML-MFC for heavy metal reduction.
Key findings
- [object Object]
- [object Object]
- [object Object]
Keywords
Identifiers
- Journal
- IOP Conference Series: Earth and Environmental Science
- Year