Improving the Efficiency of Open Cathode PEM Fuel Cell Through Hydrogen Flow Control Using Wavelet-Clipping
Triyanto Pangaribowo, Wahyu Mulyo Utomo, Abdul Hamid Budiman, Deni Shidqi Khaerudini +1
AI summary
70% confidenceA novel hybrid system integrating wavelet and clipping techniques is proposed to regulate hydrogen flow in OC-PEMFC, improving efficiency and accuracy under constant load conditions.
Generated by MESSAI extraction pipeline · review against source PDF
Literature priors
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
Reported parameters
The author’s reported value (▼) sits on top of the literature distribution from MESS-Parameters. Values outside the band are flagged as outliers.
3 extracted values
View extracted valuesOpen in lab for full controls, parameter editing, and template overlays.
Open in lab →What they did
- System
- MFC
What worked
No outcome metrics extracted yet.
Abstract
Open cathode proton exchange membrane fuel cells (OC-PEMFC) are devices that produce electrical energy through an electrochemical reaction between hydrogen and oxygen gas. Rapid load changes often lead to fluctuations in the flow of hydrogen entering the OC-PEMFC system. Increased load directly correlates with higher hydrogen gas consumption. However, if there is a delay in adjusting the gas flow rate to changes in load, it can trigger fluctuations in the amplitude and frequency of the output voltage. This fluctuation ultimately disrupts the stability of the power supply to the load, and reducing efficiency. Therefore, this paper presents a novel hybrid system that integrates wavelet and clipping techniques to regulate a more stable hydrogen flow, enhancing efficiency and accuracy under constant load conditions. A wavelet control system is used to mitigate noise, coupled with amplitude limitation through clipping techniques. This control system is implemented in OC-PEMFC model that is validated with experimental data. The performance analysis of this hybrid system reveals a 1.95 % increase in efficiency and attains high accuracy, as evidenced by a low ISE value of 0.028 during interference.
Key findings
- A 1.95% increase in efficiency is achieved with the proposed hybrid system.
- The system attains high accuracy with a low ISE value of 0.028.
- The hybrid system effectively mitigates noise and amplitude fluctuations in hydrogen flow.
Keywords
Identifiers
- Journal
- Journal of Robotics and Control (JRC)
- Year
- 2024