Biofilm Density on the Electrode is Positively Correlated with the Bioelectricity of the Microbial Fuel Cell of Fisheries Wastewater
Bustami Ibrahim, Uju Uju, Alvindo Chrisna Mukti
AI summary
70% confidenceThis study investigated the effects of electrode distance on the performance of a microbial fuel cell (MFC) using fish processing wastewater. The results showed a positive correlation between biofilm density and electricity production, but no effect of electrode distance on biofilm density. The MFC system was able to reduce pollutant loads, but with varying efficiency.
Generated by MESSAI extraction pipeline · review against source PDF
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
Open in lab for full controls, parameter editing, and template overlays.
Open in lab →What they did
- System
- MFC
What worked
No outcome metrics extracted yet.
Abstract
Microbial fuel cell (MFC) is a bioreactor utilizing bacteria as electrocatalysts to convert bioenergy from biomass into electrical energy. The aim of this research were to determine the effects of the electrode distance on the bacterial density and the electrical value generated by the MFC as well as to evaluate the ability of MFC in reducing the pollutant. Single chamber MFC system with various electrode distances including 2 cm, 4 cm, and 6 cm were assembled. The wastewater of fish pindang processing was used as the medium for the MFC. The results showed that the distance had no effect on the biofilm density of the electrode and the reduction of the wastewater pollutant load. However, the distance affected the electrical value of the MFC. Biofilm density on the MFC electrode after 120 hours was 0.65-6.46 CFU/ cm². The highest voltage was obtained from the 6 cm electrode distance with the voltage 0.38±0.01 V. Positive correlation (R² = 0.99) between microbial density and electricity produced at the cathode was observed, but weak at the anoda (R² = 0.47). The MFC system could decrease the BOD value up to 50.78% and COD up to 33.29%, however the TAN value was increased to 6 mg/L.
Key findings
- Biofilm density on the MFC electrode was positively correlated with electricity production (R² = 0.99)
- Electrode distance affected the electrical value of the MFC, with the highest voltage obtained from the 6 cm electrode distance
- The MFC system was able to reduce BOD and COD values by 50.78% and 33.29%, respectively
Keywords
Identifiers
- Journal
- Jurnal Pengolahan Hasil Perikanan Indonesia
- Year
- 2019