AI summary

70% confidence

A combined system of microbial fuel cell and intermittently aerated biological filter was designed and operated in an energy self-sufficient manner, achieving 93.9% SCOD removal and 91.7% TCOD removal.

Generated by MESSAI extraction pipeline · review against source PDF

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

138 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC
Substrate
synthetic mixture

What worked

No outcome metrics extracted yet.

Abstract

Abstract Energy self-sufficiency is a highly desirable goal of sustainable wastewater treatment. Herein, a combined system of a microbial fuel cell and an intermittently aerated biological filter (MFC-IABF) was designed and operated in an energy self-sufficient manner. The system was fed with synthetic wastewater (COD = 1000 mg L −1 ) in continuous mode for more than 3 months at room temperature (~25 °C). Voltage output was increased to 5 ± 0.4 V using a capacitor-based circuit. The MFC produced electricity to power the pumping and aeration systems in IABF, concomitantly removing COD. The IABF operating under an intermittent aeration mode (aeration rate 1000 ± 80 mL h −1 ) removed the residual nutrients and improved the water quality at HRT = 7.2 h. This two-stage combined system obtained 93.9% SCOD removal and 91.7% TCOD removal (effluent SCOD = 61 mg L −1 , TCOD = 82.8 mg L −1 ). Energy analysis indicated that the MFC unit produced sufficient energy (0.27 kWh m −3 ) to support the pumping system (0.014 kWh m −3 ) and aeration system (0.22 kWh m −3 ). These results demonstrated that the combined MFC-IABF system could be operated in an energy self-sufficient manner, resulting to high-quality effluent.

Key findings

  • The system produced sufficient energy to support the pumping and aeration systems.
  • The MFC unit produced 0.27 kWh m⁻³ of energy.
  • The system achieved 93.9% SCOD removal and 91.7% TCOD removal.

Keywords

AerationEffluentMicrobial fuel cellWastewaterPulp and paper industrySewage treatment

Identifiers

Journal
Scientific Reports
Year
2015