AI summary

70% confidence

A microbial fuel cell (MFC) was used to remediate 1,4-dioxane-contaminated groundwater, with cometabolic degradation increasing removal by 10-52% and maximum power production by 18-89 mW/m³.

Generated by MESSAI extraction pipeline · review against source PDF

Literature priors

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Distribution

Reported parameters

The author’s reported value (▼) sits on top of the literature distribution from MESS-Parameters. Values outside the band are flagged as outliers.

Coulombic efficiency8.8%

3 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC

What worked

No outcome metrics extracted yet.

Abstract

Abstract A two‐chambered microbial fuel cell (MFC) was used for the first time for the remediation of an emerging contaminant—1,4‐dioxane in its anode chamber. Groundwater historically detected 1,4‐dioxane contamination was sampled from a Superfund site. Comparative study was carried out between metabolic (i.e., 1,4‐dioxane as sole carbon source) and cometabolic (i.e., 1,4‐dioxane and methanol as carbon sources) anodic degradations. It was found that cometabolic degradation increased 1,4‐dioxane removal by 10%–52% after 7 days and increased maximum power production of the MFC by 18% to 88.9 mW/m 3 . Oxalic acid was detected as a main metabolic degradation product. Beside oxalic acid, acetic acid and isopropanol were also detected as main products for cometabolic degradation. The presence of a biofilm for 1,4‐dioxane anodic degradation was observed by a scanning electron microscopy. Phyla of Bacteroidetes, Firmicutes, and Proteobacteria, as well as a variety of species, were identified for the first time—especially Rikenella sp. and Solitalea canadensis , whose relative abundances were the highest of 18.8% and 24.0% for metabolic and cometabolic degradation, respectively. This study provided an innovative and sustainable approach for 1,4‐dioxane anodic biodegradation, which would be potentially utilized for remediation of groundwater contaminated by 1,4‐dioxane. Practitioner points Groundwater contaminated with 1,4‐dioxane was remediated in the anode chamber of a two‐chambered microbial fuel cell. Cometabolic pathway increased 1,4‐dioxane removal and power production of the MFC compared to metabolic pathway. The presence of a biofilm for 1,4‐dioxane anodic degradation was observed, and oxalic acid was a main degradation product. This study would be potentially utilized for 1,4‐dioxane‐contaminated groundwater remediation with simultaneous energy production. External voltage supply for bioelectrochemical remediation of groundwater would potentially be reduced when treating chlorinated hydrocarbons co‐occurred with 1,4‐dioxane.

Key findings

  • Cometabolic degradation increased 1,4-dioxane removal by 10-52% after 7 days.
  • Cometabolic degradation increased maximum power production of the MFC by 18-89 mW/m³.
  • Oxalic acid, acetic acid, and isopropanol were detected as main degradation products.

Keywords

Environmental remediationMicrobial fuel cellGroundwaterContaminated groundwaterWaste management1,4-Dioxane

Identifiers

Journal
Water Environment Research
Year
2019