AI summary

70% confidence

A constructed wetland connected to an air-cathode microbial fuel cell (ACMFC) generated significantly more bioelectricity and treated wastewater more efficiently than a constructed wetland connected to a traditional microbial fuel cell (MFC).

Generated by MESSAI extraction pipeline · review against source PDF

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

5 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC

What worked

No outcome metrics extracted yet.

Abstract

Abstract The aim of this study was to investigate the different performance of bioelectricity generation and wastewater treatment between constructed wetland (CW) respectively coupled with air-cathode microbial fuel cell (ACMFC) and microbial fuel cell (MFC) under a fed-batch mode. During a 75-day-operation, the voltage of CW-ACMFC and CW-MFC ranged from 0.36 to 0.52 V and from −0.04 to 0.07 V, indicating that the bioenergy output of CW-ACMFC was significantly higher than that of CW-MFC system. In addition, the maximum of power density of CW-ACMFC and CW-MFC was 4.21 and 0.005 mW m⁻². Notably, the chemical oxygen demand (COD) and NH3-N removal efficiency of CW-ACMFC was slightly higher than that in CW-MFC, which resulted from a higher voltage accelerating the transport of electron donors and the growth of microorganisms and plants. This study possesses a probability of using ACMFC coupled with CW to enhance the pollutant removal performance in CW system.

Key findings

  • The voltage of the CW-ACMFC system was 0.36-0.52 V, while the voltage of the CW-MFC system was -0.04 to 0.07 V.
  • The maximum power density of the CW-ACMFC system was 4.21 mW m⁻², while the maximum power density of the CW-MFC system was 0.005 mW m⁻².
  • The CW-ACMFC system had a slightly higher COD and NH3-N removal efficiency than the CW-MFC system.

Keywords

Microbial fuel cellConstructed wetlandCathodeBioenergyChemical oxygen demandWastewater

Identifiers

Journal
Water Science and Technology
Year
2018