AI summary

70% confidence

A novel MFC-based BOD sensor was developed using MnO2 catalyst, showing optimal performance with β-MnO2 and long-term stability over 1.5 years.

Generated by MESSAI extraction pipeline · review against source PDF

Extraction

Reported parameters

4 extracted values

View extracted values

No 3D model is mapped to this paper yet. Parameter ranges above still place reported values on the literature distribution.

What they did

System
MBES

What worked

No outcome metrics extracted yet.

Abstract

A novel microbial fuel cell (MFC)-based biosensor was designed for continuous monitoring of biochemical oxygen demand (BOD) in real wastewater. To lower the material cost, manganese dioxide (MnO2) was tested as an innovative cathode catalyst for oxygen reduction in a single chamber air-cathode MFC, and two different crystalline structures obtained during synthesis of MnO2 (namely β- and γ-MnO2) were compared. The BOD sensor was studied in a comprehensive way, using both sodium acetate solution and real domestic wastewater (DWW). The optimal performance of the sensor was obtained with a β-MnO2 catalyst, with R2 values of 0.99 and 0.98 using sodium acetate solution and DWW, respectively. The BOD values predicted by the β-MnO2 biosensor for DWW were in agreement with the BOD5 values, determined according to standard methods, with slight variations in the range from 3% to 12%. Finally, the long-term stability of the BOD biosensor was evaluated over 1.5 years. To the best of our knowledge, this is the first report of an MFC BOD sensor using an MnO2 catalyst at the cathode; the feasibility of using a low-cost catalyst in an MFC for online measurement of BOD in real wastewater broadens the scope of applications for such devices.

Key findings

  • The BOD sensor using β-MnO2 catalyst showed R2 values of 0.99 and 0.98 with sodium acetate solution and DWW, respectively.
  • The BOD values predicted by the β-MnO2 biosensor for DWW were in agreement with the BOD5 values with slight variations.
  • The long-term stability of the BOD biosensor was evaluated over 1.5 years with no significant degradation.

Keywords

Term (time)Microbial fuel cellCatalysisFuel cellsBiochemical engineeringChemical engineering

Identifiers

Journal
International Journal of Molecular Sciences
Year
2017