AI summary

65% confidence

A 1 MW Direct Fuel Cell power plant at California State University, Northridge, utilizes a waste heat recovery system to provide heating hot water for campus buildings and domestic water.

Generated by MESSAI extraction pipeline · review against source PDF

Literature priors

Generic MECRepresentative model
Click to animate flow
loading 3D model…

Representative MEC — matched on the paper’s system type only, not its reactor or geometry.

Distribution

Reported parameters

The author’s reported value (▼) sits on top of the literature distribution from MESS-Parameters. Values outside the band are flagged as outliers.

Coulombic efficiency74%

1 extracted value

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MEC

What worked

Coulombic efficiency74.0%best of 2

Abstract

A 1 MW Direct Fuel Cell® (DFC) power plant began operation at California State University, Northridge (CSUN) in January, 2007. This plant is currently the largest fuel cell plant in the world operating on a university campus. The plant consists of four 250 kW DFC300MA™ fuel cell units purchased from FuelCell Energy, Inc., and a waste heat recovery system which produces dual heating hot water loops for campus building ventilation heating, and domestic water and swimming pool heating water for the University Student Union (USU). The waste heat recovery system was designed by CSUN’s Physical Plant Management and engineering student staff personnel to accommodate the operating conditions required by the four individual fuel cell units as well as the thermal energy needs of the campus. A Barometric Thermal Trap (BaTT) was designed to mix the four fuel cell exhaust streams prior to flowing through a two stage heat exchanger unit. The BaTT is required to maintain an appropriate exhaust back pressure at the individual fuel cell units under a variety of operating conditions and without reliance on mechanical systems for control. The two stage heat exchanger uses separate coils for recovering sensible and latent heat in the exhaust stream. The sensible heat is used for heating water for the campus’ hot water system. The latent heat represents a significant amount of energy because of the high steam content in the fuel cell exhaust, although it is available at a lower temperature. CSUN’s design is able to make effective use of the latent heat because of the need for swimming pool heating and hot water for showers in an adjacent recreational facility at the USU. Design calculations indicate that a Combined Heat and Power efficiency of 74% is possible. This paper discusses the integration of the fuel cell plant into the campus’ energy systems, and presents preliminary operational data for the performance of the heat recovery system.

Key findings

  • The plant consists of four 250 kW DFC300MA fuel cell units and a waste heat recovery system.
  • A Barometric Thermal Trap (BaTT) was designed to mix the four fuel cell exhaust streams prior to flowing through a two stage heat exchanger unit.
  • The waste heat recovery system produces dual heating hot water loops for campus building ventilation heating, and domestic water and swimming pool heating water.

Keywords

Waste heatHeat recovery ventilationWaste managementHeat exchangerWaste heat recovery unitLatent heat

Identifiers

Journal
Volume 15: Sustainable Products and Processes
Year
2006