Investigation of performance losses in microbial fuel cells with low platinum loadings on air-cathodes
Eda Sonmez, Burcak Avci, Nourhan Mohamed, Hakan Bermek
AI summary
70% confidenceReducing platinum loadings on air-cathodes in MFCs resulted in significant performance losses, with maximum power density decreasing by 38-84%.
Generated by MESSAI extraction pipeline · review against source PDF
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
Open in lab for full controls, parameter editing, and template overlays.
Open in lab →What they did
- System
- MFC
- Substrate
- pure compound
What worked
No outcome metrics extracted yet.
Abstract
The effect of platinum (Pt) loadings of air-cathodes in the 0-0.5 mg cm⁻² range on single chamber microbial fuel cell (MFC) performance and cathode impedance was evaluated. In MFC tests, reducing benchmarking Pt loading of 0.5 mg cm⁻² to 0.1-0 mg cm⁻² decreased maximum power density by between 38% and 84%. The decrease in cathode open circuit potential with reduced loadings was small down to a catalyst loading of 0.03 mg cm⁻², but was significant when the loading was further reduced to 0.01 or 0 mg cm⁻². Impedance measurements of cathodes revealed that both charge-transfer and diffusion resistance increase with decreasing catalyst loadings on cathodes. Charge-transfer resistance of benchmarking cathode increased to a small extent when loadings were reduced to 0.1-0.03 mg cm⁻². Below 0.03 mg cm⁻², dramatic increase of charge-transfer resistance suggested that 0.03 mg cm⁻² can be considered as the minimum Pt loading for which kinetic limitations are not of great concern and can be overcome to a large extent compared to lower loadings. In comparison to charge-transfer resistance, diffusion resistance differed more significantly between the loadings of 0.03 and 0.5 mg cm⁻²; and it was therefore the main component that changed the internal resistance of these cathodes.
Key findings
- Decrease in cathode open circuit potential was small down to 0.03 mg cm⁻² Pt loading, but significant at 0.01 or 0 mg cm⁻².
- Charge-transfer resistance increased with decreasing Pt loadings, with a dramatic increase below 0.03 mg cm⁻².
- Diffusion resistance differed significantly between 0.03 and 0.5 mg cm⁻² Pt loadings.
Keywords
Identifiers
- Journal
- The European Chemistry and Biotechnology Journal
- Year
- 2024