AI summary

70% confidence

Reducing platinum loadings on air-cathodes in MFCs resulted in significant performance losses, with maximum power density decreasing by 38-84%.

Generated by MESSAI extraction pipeline · review against source PDF

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

178 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC
Substrate
pure compound

What worked

No outcome metrics extracted yet.

Abstract

The effect of platinum (Pt) loadings of air-cathodes in the 0-0.5 mg cm⁻² range on single chamber microbial fuel cell (MFC) performance and cathode impedance was evaluated. In MFC tests, reducing benchmarking Pt loading of 0.5 mg cm⁻² to 0.1-0 mg cm⁻² decreased maximum power density by between 38% and 84%. The decrease in cathode open circuit potential with reduced loadings was small down to a catalyst loading of 0.03 mg cm⁻², but was significant when the loading was further reduced to 0.01 or 0 mg cm⁻². Impedance measurements of cathodes revealed that both charge-transfer and diffusion resistance increase with decreasing catalyst loadings on cathodes. Charge-transfer resistance of benchmarking cathode increased to a small extent when loadings were reduced to 0.1-0.03 mg cm⁻². Below 0.03 mg cm⁻², dramatic increase of charge-transfer resistance suggested that 0.03 mg cm⁻² can be considered as the minimum Pt loading for which kinetic limitations are not of great concern and can be overcome to a large extent compared to lower loadings. In comparison to charge-transfer resistance, diffusion resistance differed more significantly between the loadings of 0.03 and 0.5 mg cm⁻²; and it was therefore the main component that changed the internal resistance of these cathodes.

Key findings

  • Decrease in cathode open circuit potential was small down to 0.03 mg cm⁻² Pt loading, but significant at 0.01 or 0 mg cm⁻².
  • Charge-transfer resistance increased with decreasing Pt loadings, with a dramatic increase below 0.03 mg cm⁻².
  • Diffusion resistance differed significantly between 0.03 and 0.5 mg cm⁻² Pt loadings.

Keywords

CathodeMicrobial fuel cellDiffusionInternal resistancePlatinumComposite material

Identifiers

Journal
The European Chemistry and Biotechnology Journal
Year
2024