Microbial fuel-cell-based toxicity sensor for fast monitoring of acidic toxicity
Yu J. Shen, Olivier Lefebvre, Zi Tan, How Y. Ng
AI summary
70% confidenceA microbial fuel cell (MFC) was used to detect acidic toxicity in wastewater by monitoring a rapid decrease in voltage after adding HCl, with a subsequent recovery.
Generated by MESSAI extraction pipeline · review against source PDF
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
Open in lab for full controls, parameter editing, and template overlays.
Open in lab →What they did
- System
- MFC
What worked
No outcome metrics extracted yet.
Abstract
Wastewater may contain various potential toxicants. A microbial fuel cell (MFC) is a device in which bacteria convert the chemical energy into electricity. If a toxic event occurs, microbial activity is inhibited and thus the power output of the MFC decreases. Therefore, an MFC could serve as an early toxicity warning device. A real-time biomonitoring system was developed using MFCs to detect the inflow of toxic substances into wastewater treatment systems. After the MFCs reached steady state, a toxic incident was created by adding HCl into the wastewater to alter its pH. Consequently, a rapid decrease in voltage was observed immediately, followed by a subsequent recovery. The optimal MFC design was a single-chamber air cathode MFC, where the anode and cathode were separated by a Selemion proton exchange membrane. Under an external resistance of 5 Ω, the maximum power averaged 0.23 ± 0.023 mW with domestic wastewater. The optimized MFC showed high sensitivity and fast recovery when exposed to the acidic toxic event. When the hydraulic retention time was decreased from 22 to 3.5 min, sensitivity of the MFC increased substantially. Finally, the extent of inhibition observed was found to be related to the toxicity level, suggesting that a dosage–response relationship exists.
Key findings
- The MFC showed high sensitivity and fast recovery when exposed to acidic toxic events.
- Decreasing hydraulic retention time from 22 to 3.5 min increased the sensitivity of the MFC.
- The optimized MFC design was a single-chamber air cathode MFC with a Selemion proton exchange membrane.
Keywords
Identifiers
- Journal
- Water Science and Technology
- Year
- 2012