The effects of electrode spacing on the performance of microbial fuel cells under different substrate concentrations
Chi-Yuan Lee, Ya-Ni Huang
AI summary
70% confidenceThis study examines the effects of electrode spacing on microbial fuel cell performance under varying substrate concentrations, finding that organic removal is related to substrate concentration but not electrode spacing. The best power output was achieved at an electrode spacing of 5.8 cm and a substrate concentration of 300 mg COD/L. The relationship between electricity generation and substrate concentration can be modeled using Monod-type kinetics.
Generated by MESSAI extraction pipeline · review against source PDF
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
Open in lab for full controls, parameter editing, and template overlays.
Open in lab →What they did
- System
- MFC
What worked
No outcome metrics extracted yet.
Abstract
In this study, the electricity generation and organic removal in microbial fuel cells (MFCs) were examined for electrode spacing (ES) covering 5.8, 10.2, 15.1, and 19.5 cm, and for each ES the MFCs were discharged with a series of influent substrates (CODin). Results indicate that organic removal was related to CODin but not to ES. Best chemical oxygen demand (COD) removals of 64–71% could be achieved at CODin around 100 mg COD/L (0.11–0.14 kg COD/m³-day). Best power output 3.32 mW/m² occurred at ES 5.8 cm and nominal CODin 300 mg COD/L. For every ES, the relationship of electricity generation to local substrate near anode (CODad) could be adequately modeled by Monod-type kinetics. The estimated kinetic constants involve maximum current production, Imax, 15.3–19.6 mA/m²; maximum attainable power output, Pp,max, 4.0–2.5 mW/m²; half-saturation constant of current, Ksi, 22–30 mg COD/L; and half-saturation constant of power, Ksp, 24–90 mg COD/L. This study reveals that the control over ES for improving electricity generation is dependent on the level of CODad, which profoundly affects the optimal design of electrode placement.
Key findings
- Organic removal is related to CODin but not to electrode spacing
- Best power output of 3.32 mW/m² occurred at ES 5.8 cm and nominal CODin 300 mg COD/L
- Monod-type kinetics can model the relationship between electricity generation and local substrate near anode
Keywords
Identifiers
- Journal
- Water Science and Technology
- Year