70% confidenceA microbial fuel cell integrated with an anaerobic membrane filtration system was designed to evaluate bioelectricity generation and removal efficiency of organic substrate. The optimal organic loading rate was found to be 6.25 kg COD/(m³·d), resulting in a voltage and power density of 0.15 V and 13.6 mW/m³. The system showed stable effluent quality even with a short hydraulic retention time of 1.9 h.
Generated by MESSAI extraction pipeline · review against source PDF
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
Open in lab for full controls, parameter editing, and template overlays.
Open in lab →What they did
- System
- MFC
What worked
No outcome metrics extracted yet.
Abstract
A cylindrical two chambered microbial fuel cell (MFC) integrated with an anaerobic membrane filter was designed and constructed to evaluate bioelectricity generation and removal efficiency of organic substrate (glucose or domestic wastewater) depending on organic loading rates (OLRs). The MFC was continuously operated with OLRs 3.75, 5.0, 6.25, and 9.38 kg chemical oxygen demand (COD)/(m³·d) using glucose as a substrate, and the cathode chamber was maintained at 5–7 mg/L of dissolved oxygen. The optimal OLR was found to be 6.25 kgCOD/(m³·d) (hydraulic retention time (HRT) 1.9 h), and the corresponding voltage and power density averaged during the operation were 0.15 V and 13.6 mW/m³. With OLR 6.25 kgCOD/(m³·d) using domestic wastewater as a substrate, the voltage and power reached to 0.13 V and 91 mW/m³ in the air cathode system. Even though a relatively short HRT of 1.9 h was applied, stable effluent could be obtained by the membrane filtration system and the following air purging. In addition, the short HRT would provide economic benefit in terms of reduction of construction and operating costs compared with a conventional aerobic treatment process.
Key findings
- The optimal organic loading rate for the system was 6.25 kg COD/(m³·d)
- The system achieved a voltage and power density of 0.15 V and 13.6 mW/m³ using glucose as a substrate
- The system achieved a voltage and power density of 0.13 V and 91 mW/m³ using domestic wastewater as a substrate
Keywords
Identifiers
- Journal
- Water Science and Technology
- Year