Impacts of process parameters optimization on the performance of the annular single chamber microbial fuel cell in wastewater treatment
Parisa Nouri, Ghasem Najafpour Darzi
AI summary
70% confidenceThe study investigated the optimization of process parameters in an annular single chamber microbial fuel cell (ASCMFC) for efficient wastewater treatment and electricity generation. The results showed that temperature and pH significantly affected the performance of the ASCMFC, with optimal conditions at 35°C and pH 7. The study demonstrated the potential of ASCMFC in treating chocolate industry wastewater and generating electricity.
Generated by MESSAI extraction pipeline · review against source PDF
Literature priors
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
Reported parameters
The author’s reported value (▼) sits on top of the literature distribution from MESS-Parameters. Values outside the band are flagged as outliers.
6 extracted values
View extracted valuesOpen in lab for full controls, parameter editing, and template overlays.
Open in lab →What they did
- System
- MFC
What worked
No outcome metrics extracted yet.
Abstract
Energy harvest from optimized annular single chamber microbial fuel cell (ASCMFC) with novel configuration, which treats chocolate industry wastewater, was investigated. In this study, optimization of operational parameters of the ASCMFC in terms of efficiency water‐soluble organic matter reduction and capability of electricity generation was evaluated. During the experiment, effluent from the anode compartment was examined through current and power density curves for variation in temperature and pH, chemical oxygen demand (COD), and turbidity removal, and substrate concentration. The performance analyzed at different temperature ranges such as 25, 30, 35, and 40°C, which showed 88% increase by uprising temperature from 25 to 35°C. The ASCMFC was used to produce electricity by adjusting pH between 5 and 9 at resistance of 100 Ω. Under the condition of pH 7 power density (16.75 W/m 3 ) was highest, which means natural pH is preferred to maximize microbial activities. Wastewater concentration with COD of 700 and 1400 mg/L were investigated to determine its affection on current production. Reduction of current density was observed due to decrease in wastewater concentration. Significant reduction in COD and turbidity of effluent were 91 and 78%, respectively. The coulombic efficiency of 45.1% was achieved.
Key findings
- 88% increase in performance by increasing temperature from 25 to 35°C
- Highest power density of 16.75 W/m³ at pH 7
- Reduction in current density with decrease in wastewater concentration
Keywords
Identifiers
- Journal
- Engineering in Life Sciences
- Year
- 2016