Removal of Phosphorus from Domestic Sewage by a Constructed Wetland Coupled Microbial Fuel Cell System
Shuang Yu, Peng Dou, Yue Yin, Peijing Wang +3
AI summary
70% confidenceA constructed wetland coupled microbial fuel cell system effectively removed phosphorus from domestic sewage, with garnet and magnesia substrates achieving 92.4% and 80.3% removal efficiencies, respectively. The system also generated electricity, with the garnet system producing a higher output voltage. The phosphorus removal mechanism involved complex adsorption and ion exchange reactions.
Generated by MESSAI extraction pipeline · review against source PDF
Representative dual-chamber H-cell — matched on the paper’s reported configuration, not its exact geometry.
Open in lab for full controls, parameter editing, and template overlays.
Open in lab →What they did
- System
- MFC
- Substrate
- synthetic mixture
- Inoculum
- microorganisms in the soil and in the electrode within the wetland sediments
What worked
No outcome metrics extracted yet.
Abstract
Abstract A constructed wetland (CW) coupled microbial fuel cell (MFC) system that treats wastewater and generates electricity was constructed. The total phosphorus in the simulated domestic sewage was used as the treatment target, and the optimal phosphorus removal effect and electricity generation were determined by comparing the changes in substrates, hydraulic retention times, and microorganisms. The mechanism underlying phosphorus removal was also analyzed. The experimental results showed that the best removal efficiencies of the two CW-MFC systems that used magnesia and garnet as substrates were 80.3% and 92.4%, respectively. Phosphorus removal by the garnet matrix mainly depends on a complex adsorption process whereas the magnesia system relies on ion exchange reactions. The CW-MFC system can also generate electricity. The highest output voltage and stable voltage of the garnet system were both higher than those of the magnesia system. The maximum stable voltage of the garnet device was 500 mV, while that of the magnesia device was 290 mV. The microorganisms in the soil and in the electrode within the wetland sediments also substantially changed, indicating that microorganisms positively respond to the removal of organic matter and power generation. Combining the advantages of constructed wetlands and microbial fuel cells also improves phosphorus removal in the coupled system. Therefore, when studying a CW-MFC system, the selection of electrode materials, matrix, and system structure should be taken into account in order to find a method that will improve the power generation capacity of the system and remove phosphorus.
Key findings
- Garnet substrate achieved 92.4% phosphorus removal efficiency
- Magnesia substrate achieved 80.3% phosphorus removal efficiency
- Garnet system produced a maximum stable voltage of 500 mV, higher than the magnesia system's 290 mV
Keywords
Identifiers
- Journal
- Research Square
- Year
- 2021