Ozone exposure at 1000 vppm in air causes reversible voltage loss and irreversible damage to a PEMFC after multiple injections, leading to Pt dissolution and re-precipitation in the membrane and GDL.

Generated by MESSAI extraction pipeline · review against source PDF

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

7 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC

What worked

No outcome metrics extracted yet.

Abstract

Abstract The effects of ozone at concentrations near 1000 vppm in air on the performance of a single polymer electrolyte membrane fuel cell (PEMFC) were investigated. Ozone was injected to the cathode alternately with far longer operation periods at 0.54 A cm –2 with ozone‐free air. Impedance spectra were recorded before, during and after exposure to ozone. After the first ozone injection, the loss in voltage was reversible, so were the changes in the resistances of the cell. Subsequent injection periods damaged irreversibly the PEMFC assembly. TEM observations with energy dispersive X‐ray spectroscopy analysis of the various parts of the PEMFC assembly together with the variations of the resistances allowed the ageing mechanism to be highlighted. Ozone was shown to allow partial dissolution of the Pt of the cathode catalyst. The charge transfer resistance was noticeably increased accordingly. Platinum re‐precipitated in the membrane bulk, and was also observed in the cathode‐side GDL. In addition, the likely degradation of the polymer near the triple‐point in the cathode could hinder gas solubility and water removal, as indicated by larger diffusion resistances.

Key findings

  • Ozone exposure causes reversible voltage loss and changes in cell resistances.
  • Multiple ozone injections lead to irreversible damage to the PEMFC assembly.
  • Pt dissolution and re-precipitation occur in the membrane and GDL.

Keywords

OzoneCathodeElectrolyteProton exchange membrane fuel cellDielectric spectroscopyMembrane

Identifiers

Journal
Fuel Cells
Year
2009