The performance of a microbial fuel cell (MFC) was evaluated under different operating temperatures, with the highest COD removal efficiency and power density achieved at 40°C.

Generated by MESSAI extraction pipeline · review against source PDF

Literature priors

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Distribution

Reported parameters

The author’s reported value (▼) sits on top of the literature distribution from MESS-Parameters. Values outside the band are flagged as outliers.

Coulombic efficiency84%

7 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC

What worked

No outcome metrics extracted yet.

Abstract

The performance of dual chambered mediator-less microbial fuel cell (MFC) operated under batch mode was evaluated under different operating temperatures, ranging between 20 and 55 °C, with step increase in temperature of 5 °C. Synthetic wastewater with sucrose as carbon source having chemical oxygen demand (COD) of 519–555 mg/L was used in the study. Temperature was a crucial factor in the performance of MFCs for both COD removal and electricity production. The MFC demonstrated highest COD removal efficiency of 84% and power density normalized to the anode surface area of 34.38 mW/m² at operating temperature of 40 °C. Higher VSS to SS ratio was observed at the operating temperature between 35 and 45 °C. Under different operating temperatures the observed sludge yield was in the range of 0.05 to 0.14 g VSS/g COD removed. The maximum Coulombic and energy efficiencies were obtained at 40 °C, with values of 7.39 and 13.14%, respectively. Internal resistance of the MFC decreased with increase in operating temperature. Maximum internal resistance of 1,150 Ω was observed when the MFC was operated at 20 °C; whereas the minimum internal resistance (552 Ω) was observed at 55 °C.

Key findings

  • The MFC demonstrated highest COD removal efficiency of 84% and power density normalized to the anode surface area of 34.38 mW/m² at operating temperature of 40 °C.
  • Higher VSS to SS ratio was observed at the operating temperature between 35 and 45 °C.
  • The maximum Coulombic and energy efficiencies were obtained at 40 °C, with values of 7.39 and 13.14%, respectively.
  • Internal resistance of the MFC decreased with increase in operating temperature.

Keywords

Microbial fuel cellWaste managementFuel cells