Optimization of a constructed wetland-microbial fuel cell system for Cr(VI) removal from wastewater and power generation performance
Yucui Shi, Yongwei Li, Qing Liu, Shaohong You
AI summary
70% confidenceA constructed wetland-microbial fuel cell system effectively removes Cr(VI) from wastewater and generates electricity, with optimal operating parameters including a COD concentration of 300 mg/dm³, Cr(VI) concentration of 80 mg/dm³, and hydraulic retention time of 3 days.
Generated by MESSAI extraction pipeline · review against source PDF
Representative tubular / upflow MFC — matched on the paper’s reported configuration, not its exact geometry.
Open in lab for full controls, parameter editing, and template overlays.
Open in lab →What they did
- System
- MFC
- Substrate
- synthetic mixture
- Inoculum
- mixed culture from anaerobic sludge (Liquan Brewery, Guilin) acclimated for 1 week. Dominant electrogenic bacteria Geobacter and metal dissimilatory reducing bacteria Acinetobacter detected.
What worked
No outcome metrics extracted yet.
Abstract
A new type of bioelectrochemical system features a constructed wetland (CW) coupled with a microbial fuel cell (MFC) to treat Cr(VI) wastewater while generating electricity. The optimal operating parameters for treating wastewater containing Cr(VI) are discussed. The results show that the CW-MFC system is more effective in the treatment of Cr(VI)-containing wastewater and generating electricity. A COD concentration of 300 mg/dm 3 corresponded to the greatest COD and Cr(VI) removal rates with a maximum power density of 505.62 mW/m 3 , whereas a Cr(VI) concentration of 80 mg/dm 3 yielded the greatest COD removal rate, with a maximum power density of 484.43 mW/m 3 . A hydraulic retention time (HRT) of 3 days yielded the largest pollutant removal rates with a maximum power density of 479.21 mW/m 3 . Considering that the comprehensive operating conditions of CW-MFC are based on planting plants, the COD concentration is 300 mg/dm 3 , the Cr(VI) concentration is 80 mg/dm 3 , and the HRT is 3 days. The abundance of electrogenic bacteria Geobacter and metal dissimilatory reducing bacteria Acinetobacter in CW-MFC is higher than that in the control group. The results of this study provide theoretical guidance for determining the optimal operating conditions and energy recovery of the CW-MFC system for treating chromium wastewater.
Key findings
- [object Object]
- [object Object]
- [object Object]
Keywords
Identifiers
- Journal
- Environment Protection Engineering
- Year