Abstract

A miniature-microbial fuel cell (mini-MFC, chamber volume: 1.2 mL) was used to monitor biofilm development from a pure culture of Shewanella oneidensis DSP10 on graphite felt (GF) under minimal nutrient conditions. ESEM evidence of biofilm formation on GF is supported by substantial power density (per device cross-section) from the mini-MFC when using an acellular minimal media anolyte (1500 mW/m²). These experiments demonstrate that power density per volume for a biofilm flow reactor MFC should be calculated using the anode chamber volume alone (250W/m³), rather than with the full anolyte volume. Two oxygen reduction cathodes (uncoated GF or a Pt/vulcanized carbon coating on GF) were also compared to a cathode using uncoated GF and a 50mM ferricyanide catholyte solution. The Pt/C-GF (2-4% Pt by mass) electrodes with liquid cultures of DSP10 produced one order of magnitude larger power density (150W/m³) than bare graphite felt (12W/m³) in this design. These advances are some of the required modifications to enable the mini-MFC to be used in real-time, long-term environmental power generating situations.

Keywords

Shewanella oneidensisMicrobial fuel cellCathodeAnodeVolume (thermodynamics)Biofilm

Identifiers

PubMed
16939710
Journal
Biosensors and Bioelectronics
Year
2007