Influence of Cathodal Performance on Electricity Generation of Microbial Fuel Cell with Refinery Oil Wastewater as Fuel
Xuan Guo, Ya Li Zhan, Shao Hui Guo, Guang Xu Yan +3
AI summary
70% confidenceA double-chambered microbial fuel cell (MFC) was constructed to investigate the feasibility of electricity generation using microbial fuel cell with refinery oil wastewater as its fuel and the influence of cathodal performance. Results indicated that refinery oil wastewater could be used as fuel in MFCs to generate electricity; catholyte type could influence the electricity generation of MFCs directly and Fe (Ⅲ)-EDTA was the best choice, voltage generation and stable operational period of which were highest and longest; voltage generation increased following with catholyte concentration linear but had little relation to cathode areas.
Generated by MESSAI extraction pipeline · review against source PDF
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
Open in lab for full controls, parameter editing, and template overlays.
Open in lab →What they did
- System
- MFC
What worked
No outcome metrics extracted yet.
Abstract
A double-chambered microbial fuel cell (MFC) was constructed to investigate the feasibility of electricity generation using microbial fuel cell with refinery oil wastewater as its fuel and the influence of cathodal performance. Results indicated that refinery oil wastewater could be used as fuel in MFCs to generate electricity; catholyte type could influence the electricity generation of MFCs directly and Fe (Ⅲ)-EDTA was the best choice, voltage generation and stable operational period of which were highest and longest; voltage generation increased following with catholyte concentration linear but had little relation to cathode areas.
Key findings
- Results indicated that refinery oil wastewater could be used as fuel in MFCs to generate electricity; catholyte type could influence the electricity generation of MFCs directly and Fe (Ⅲ)-EDTA was the best choice, voltage generation and stable operational period of which were highest and longest; voltage generation increased following with catholyte concentration linear but had little relation to cathode areas.
Keywords
Identifiers
- Journal
- Advanced Materials Research
- Year
- 2012