AI summary

70% confidence

This MFC study abstract Background The critical MFC design challenge is to increase anode surface area. A novel FAB–MFC integrated system was developed and evaluated for domestic wastewater treatment.

Generated by MESSAI extraction pipeline · review against source PDF

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

88 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC
Substrate
real wastewater

What worked

No outcome metrics extracted yet.

Abstract

Abstract Background The critical MFC design challenge is to increase anode surface area. A novel FAB–MFC integrated system was developed and evaluated for domestic wastewater treatment. It was operated in fed-batch flow mode at 1–3 days of HRT with 755 mg/L CODIN and 0.76 kg-COD/m3/day. The study includes anaerobic-MFC and aerobic-MFC integrated systems. Microbial electrode jacket dish (MEJ-dish) with hybrid dimension (HD) was invented, first time to authors’ knowledge, to boost anode biofilm growth. The treatment system with MEJ+ (FAB) and MEJ− (MFC) anode are called FAB–MFC and MFC, respectively. Results Fragmented variable anode biofilm thickness was observed in FAB than MFC. The FAB–MFC (FAB+) simple technique increases the anode biofilm thickness by ~ 5 times MFC. Due to HD the anode biofilm was fragmented in FAB+ system than MFC. At the end of each treatment cycle, voltage drops. All FAB+ integrated systems reduced voltage drop relative to MFC. FAB reduces voltage drops better than MFC in anaerobic-MFC from 6 to 20 mV and aerobic-MFC from 35–47 mV at 1 kΩ external load. The highest power density was achieved by FAB in anaerobic-MFC (FAB = 104 mW/m², MFC = 98 mW/m²) and aerobic-MFC integrated system (FAB = 59 mW/m², MFC = 42 mW/m²). Conclusions The ∆COD and CE between FAB and MFC could not be concluded because both setups were inserted in the same reactor. The integrated system COD removal (78–97%) was higher than the solitary MFC treatment (68–78%). This study findings support the FAB+ integrated system could be applied for real applications and improve performance. However, it might depend on influent COD, the microbial nature, and ∆COD in FAB+ and MFC, which requires further study. Graphic abstract

Key findings

  • The highest power density was achieved by FAB in anaerobic-MFC (FAB = 104 mW/m², MFC = 98 mW/m²) and aerobic-MFC integrated system (FAB = 59 mW/m², MFC = 42 mW/m²).
  • The integrated system COD removal (78–97%) was higher than the solitary MFC treatment (68–78%).

Keywords

Microbial fuel cellAnodeWastewaterBiofilmPulp and paper industryWaste management

Identifiers

Journal
Bioresources and Bioprocessing
Year
2021