Preformance of an Electrobiochemical Slurry Reactor for the Treatment of a Soil Contaminated with Lindane
Beni Camacho-Pérez, Elvira Ríos-Leal, Omar Solorza-Feria, Pedro Alberto Vazquez-Landa +5
AI summary
90% confidenceMFC research in energy, microbial. Lindane is a chlorinated pesticide known for its toxicity and persistenc...
Generated by MESSAI extraction pipeline · review against source PDF
Literature priors
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
Reported parameters
The author’s reported value (▼) sits on top of the literature distribution from MESS-Parameters. Values outside the band are flagged as outliers.
6 extracted values
View extracted valuesOpen in lab for full controls, parameter editing, and template overlays.
Open in lab →What they did
- System
- MFC
What worked
No outcome metrics extracted yet.
Abstract
Lindane is a chlorinated pesticide known for its toxicity and persistence in the environment. Recently, it has been proposed that soil microbial fuel cell technology (SMFC) could be applied to enhance the removal of organic matter, phenol, and petroleum hydrocarbon in contaminated soil with simultaneous electricity output. Yet, there is no information on the application to remediation of soils polluted with pesticides. The purpose of this research was to evaluate the biodegradation of lindane with simultaneous electricity generation in an electrobiochemical slurry reactor (EBCR). The EBCR was inoculated with a sulfate reducing inoculum acclimated to lindane, it was further characterized, and batch operated for 30 day at room temperature. No external carbon source was supplemented in the experiment 1; the substrate was the soluble natural organic matter (NOM) of the soil. In the experiment 2 the EBCR was supplemented with a stock solution of sucrose: sodium acetate: lactate to give a final concentration of 2g COD/L in the reactor. Results from electrochemical impedance spectroscopy characterization in the EBCR (Experiment 1) showed that the equivalent circuit had a high anodic resistance R1=2064 Ω, cathodic resistance R3 = 192 Ω; and electrolyte/membrane resistance R2 = 7?, totaling a relatively high overall internal resistance Rint of 2263 Ω. During the batch operation, the EBCR showed a 30% lindane removal efficiency along with a maximum volumetric power of 165 mW m⁻³.This value compared favorably with results corresponding to sediments microbial fuel cells that are used to power weather monitoring systems. The organic matter removal was very high (72% as soluble COD, NOM) whereas the coulombic efficiency was low (5.4%). The latter, although, was higher than values reported for microbial fuel cells that degraded leachate-like effluents. In Experiment 2 of the EBCR both cell characteristics and performance significantly improved. The internal resistance as determined by polarization curve was 102 Ω when the two-electrode sets were connected in parallel. During the batch operation, the EBCR showed a 78% lindane removal and a maximum power volumetric of 634 mW m⁻³, the organic matter removal was 76% and coulombic efficiency was 15%. Finally, it can be concluded that our EBCR showed a high lindane removal capability and mixing of the slurry phase was associated to improvement of bioremediation and electricity performances of the device.
Keywords
Identifiers
- Journal
- Journal of New Materials for Electrochemical Systems
- Year
- 2013