This in-vitro pilot study evaluated the impact of three different mechanical cleaning protocols (ultrasonic stainless-steel, ultrasonic PEEK, and sonic) on the adhesive bond strength of fixed orthodontic retainers after artificial calculus removal. The results indicate that the choice of instrumentation significantly influences the integrity of the adhesive bond, with specific methods causing varying degrees of weakening.

Generated by MESSAI extraction pipeline · review against source PDF

Extraction

Reported parameters

1 extracted value

View extracted values

No 3D model is mapped to this paper yet. Parameter ranges above still place reported values on the literature distribution.

Abstract

Abstract Introduction Orthodontic fixed retainers are often a predilection site for calculus build-up. However, standardized protocol for professional mechanical plaque removal (PMPR) does not yet exist that takes into account the slight weakening of the adhesive bond. Material and Methods In this in-vitro study, three cleaning protocols were evaluated: Group A: ultrasonic stainless-steel tip (Piezon PS, EMS Dental); Group B: Polyetheretherketone (PEEK) ultrasonic tip (PI Max, EMS Dental); and Group C: sonic cleaning (SiroTip S1, Sirona Dental Systems). These protocols were assigned artificial lower canine-to-canine segments with individual Twistflex retainers bonded (n = 10/group). Following artificial ageing of the adhesive bond, artificial calculus was applied and removed according to the respective cleaning protocol. After repeating twice, adhesive bond strengths were analysed. Results The Kruskal-Wallis test showed that the choice of instrumentation significantly influences the integrity of the adhesive bond (p = 0.036). Post-hoc pairwise comparisons revealed that Group A had significantly higher shear bond strength compared to Group C (p = 0.028). Conclusions This in-vitro study shows that the type of the PMPR system used has a significant influence on the shear bond strength of fixed retainers. Ultrasound-driven stainless-steel scalers appear to be more gentle than sonic-driven devices. Clinical relevance In clinical practice, the accidental debonding of retainer attachments during PMBR is a frequent complication. The present in-vitro study investigates whether specific cleaning modalities can minimize the risk of compromising the adhesive bonding. Specifically, different cleaning modalities (ultrasonic versus sonic) and various tip materials are evaluated and compared.

Key findings

  • The choice of cleaning instrumentation significantly influences the integrity of the adhesive bond (p = 0.036).
  • Ultrasonic stainless-steel tips and PEEK ultrasonic tips were compared against sonic cleaning to assess their relative effects on retainer retention.
  • No standardized protocol currently exists for professional mechanical plaque removal that accounts for potential adhesive weakening.