AI summary

90% confidence

MES research in electrode, performance. In the current study, a glassy carbon electrode (GCE) modified with graphene-CoS2 nanocompos...

Generated by MESSAI extraction pipeline · review against source PDF

Extraction

Reported parameters

35 extracted values

View extracted values

No 3D model is mapped to this paper yet. Parameter ranges above still place reported values on the literature distribution.

Abstract

In the current study, a glassy carbon electrode (GCE) modified with graphene-CoS2 nanocomposite was investigated for electrochemical sensing of ascorbic acid. The electrochemical performance of the modified electrode was examined using differential pulse voltammetry (DPV), linear sweep voltammetry (LSV) and chronoamperometry (CHA) techniques. The electrochemical behavior of ascorbic acid at the graphene-CoS2/GCE displayed a higher oxidation current and lower oxidation potential than bare GCE. Under the optimal experimental conditions, the sensor presented a good linear response between the current and the ascorbic acid concentration range of 0.15–245.0 μM, with a low detection limit of 0.05 μM. Finally, the graphene-CoS2 nanocomposite-modified GCE was applied for the determination of ascorbic acid in real samples and displayed excellent recoveries.

Keywords

Ascorbic acidChronoamperometryDifferential pulse voltammetryLinear sweep voltammetryDetection limitElectrochemical gas sensor

Identifiers

Journal
Journal of Electrochemical Science and Engineering
Year
2022