AI summary

100% confidence

Specialized MFC research in advanced-systems focusing on advanced-configuration, performance-optimization, substrates. A new type of scalable MFC was developed based on using alternating graphite fiber brush array anode modules and dual cathode modu...

Generated by MESSAI extraction pipeline · review against source PDF

Generic MFCRepresentative model
Click to animate flow
loading 3D model…

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

Extraction

Reported parameters

8 extracted values

View extracted values

Open in lab for full controls, parameter editing, and template overlays.

Open in lab →

What they did

System
MFC

What worked

No outcome metrics extracted yet.

Abstract

A new type of scalable MFC was developed based on using alternating graphite fiber brush array anode modules and dual cathode modules in order to simplify construction, operation, and maintenance of the electrodes. The modular MFC design was tested with a single (two-sided) cathode module with a specific surface area of 29 m² m⁻³ based on a total liquid volume (1.4 L; 20 m² m⁻³ using the total reactor volume of 2 L), and two brush anode modules. Three different types of spacers were used in the cathode module to provide structural stability, and enhance air flow relative to previous cassette (combined anode–cathode) designs: a low-profile wire spacer; a rigid polycarbonate column spacer; and a flexible plastic mesh spacer. The best performance was obtained using the wire spacer that produced a maximum power density of 1100 ± 10 mW m⁻² of cathode (32 ± 0.3 W m⁻³ based on liquid volume) with an acetate-amended wastewater (COD = 1010 ± 30 mg L⁻¹), compared to 1010 ± 10 mW m⁻² for the column and 650 ± 20 mW m⁻² for the mesh spacers. Anode potentials were unaffected by the different types of spacers. Raw domestic wastewater produced a maximum of 400 ± 8 mW m⁻² under fed batch conditions (wire-spacers), which is one of the highest power densities for this fuel. Over time the maximum power was reduced to 300 ± 10 mW m⁻² and 275 ± 7 mW m⁻² for the two anode compartments, with only slightly less power of 250 ± 20 mW m⁻² obtained under continuous flow conditions. In fixed-resistance tests, the average COD removal was 57 ± 5% at a hydraulic retention time of 8 h. These results show that this modular MFC design can both simplify reactor construction and enable relatively high power generation from even relatively dilute wastewater.

Keywords

AnodeCathodeMicrobial fuel cellScalabilityElectrodeOptoelectronics

Identifiers

Journal
Environmental Science: Water Research & Technology
Year
2016