Choice of the efficient flow diagram of biological wastewater treatment at municipal wastewater treatment plants
, Serhii Protsenko, Mykola Kizyeyev, +2
AI summary
90% confidenceMES research in microbial, treatment. The possibility of increasing the efficiency of municipal wastewater tre...
Generated by MESSAI extraction pipeline · review against source PDF
No 3D model is mapped to this paper yet. Parameter ranges above still place reported values on the literature distribution.
Abstract
The possibility of increasing the efficiency of municipal wastewater treatment plant (WWTP) operation by changing the flow diagram of biological wastewater treatment in aeration tanks at minimum expenses for their reconstruction is shown in the paper on the example of one of the regional centres of Ukraine. The technology of nitri-denitrification of wastewater according to the flow diagram of the two-stage modified Ludzak-Ettinger process is offered for the considered conditions. The distribution of wastewater flows and internal nitrate recycling between the individual stages of this flow diagram has been optimized in order to minimize the residual content of total nitrogen in the treated effluents. Computer dynamic modelling of biochemical processes has proved the high efficiency and reliability of the flow diagram proposed by the authors.
Keywords
Identifiers
- Journal
- Environmental Problems
- Year
- 2021