A Green Voltammetric Determination of Molnupiravir using a Disposable Screen-Printed Reduced Graphene Oxide Electrode: Application to Pharmaceutical Dosage Form and Biological Fluid
Abdelrahman Nabile, Hassan Hendawy, Randa Abdel Salam, Rasha Ahmed +3
AI summary
100% confidenceMES research in electrode, membrane. A new green-validated and highly sensitive electrochemical method for the determination of m...
Generated by MESSAI extraction pipeline · review against source PDF
Literature priors
Reported parameters
The author’s reported value (▼) sits on top of the literature distribution from MESS-Parameters. Values outside the band are flagged as outliers.
3 extracted values
View extracted valuesNo 3D model is mapped to this paper yet. Parameter ranges above still place reported values on the literature distribution.
Abstract
A new green-validated and highly sensitive electrochemical method for the determination of molnupiavir (MOV) has been developed using cyclic voltammetry. The proposed analytical platform involves the use of disposable screen-printed reduced graphene oxide 2.5% electrode (SPrGOE 2.5%) for the first time to measure MOV with high specificity. The surface morphology of the sensor was investigated by using a scanning electron microscope armed with an energy-dispersive X-ray probe. The fabricated sensor attains improved sensitivity when sodium dodecyl sulfate (SDS) surfactant was added to the supporting electrolyte solution. Thus, various factors were investigated in order to select the best supporting electrolyte for voltammetric determination of MOV, and the optimum conditions were achieved by employing 0.04 M Britton-Robinson at pH 2, 10-4 M SDS, and SPrGOE 2.5%. Well-defined MOV oxidation peaks were obtained with no reduction peaks in cyclic voltammetry using diffusion-controlled pathways. The method was validated using differential pulse voltammetry according to ICH guidelines, providing it to be precise, accurate, specific, and robust with linearity over a concentration range of 50-6017 ng/mL. The incorporation of the reduced graphene nanoparticles supported the in situ interaction between electrode surface and MOV, improved the selectivity, and reduced the detection limit to the concentration level of 15.98 ng/mL. The stability investigation demonstrated that SPrGOE 2.5% can provide high-stability behavior throughout a three-month period under refrigeration. The fabricated SPrGOE 2.5% was successfully employed for the measurement of MOV in pharmaceutical capsules and human bio-fluids without the interference of endogenous matrix components as well as the commonly used excipient.
Keywords
Identifiers
- Journal
- Preprints.org
- Year
- 2023