Self-Powered Anti-Interference Photoelectrochemical Immunosensor Enabled by a Ferroelectric Hybrid Coupled with a Platinum-Doped Peptide Hydrogel.
Hao Wang, Ying Zhao, Zhiyue Cai, Gao‐Chao Fan +1
AI summary
80% confidenceA self-powered photoelectrochemical immunosensor was developed, combining a ferroelectric hybrid photoanode with a platinum-doped peptide hydrogel biocathode, to enable sensitive and accurate detection of biomarkers in complex biofluids with reduced nonspecific interference. The ferroelectric hybrid photoanode enhances charge separation and photocurrent generation through spontaneous polarization, while the biocathode suppresses nonspecific protein adsorption with a hydrated antifouling interface. This immunosensor shows promise for early disease diagnosis and clinical monitoring.
Generated by MESSAI extraction pipeline · review against source PDF
No 3D model is mapped to this paper yet. Parameter ranges above still place reported values on the literature distribution.
Abstract
Accurate and sensitive detection of biomarkers in complex biofluids is critical for early disease diagnosis and clinical monitoring but remains challenging due to nonspecific interference from abundant proteins and reducing agents. Here, we present a novel self-powered, anti-interference photoelectrochemical (PEC) immunosensor that combines a ferroelectric hybrid photoanode with a platinum-doped peptide hydrogel (Pt-PH) biocathode. The photoanode was fabricated by in situ transformation of TiO 2 nanorod arrays into ferroelectric BaTiO 3 (BTO), followed by electrostatic self-assembly of sulfur-doped carbon nitride (SCN) quantum dots, forming an SCN/BTO/TiO 2 ferroelectric hybrid. The spontaneous polarization of ferroelectric BTO induces an internal electric field, enhancing charge separation and visible-light-driven photocurrent generation. The biocathode employs nitrogen-doped graphene (NG) as a conductive scaffold, coated with a Pt-PH layer derived from the short-peptide Fmoc-FEFKF doped with Pt nanoparticles, providing a highly hydrated antifouling interface that effectively suppresses nonspecific protein adsorption. The split-type configuration further minimizes interference from reducing agents in real biofluids. Using neuron-specific enolase as a model biomarker, the PEC immunosensor achieves sensitive, selective, and stable detection directly in physiological samples without external bias. This work offers a promising strategy for developing next-generation self-powered PEC biosensors with reliable antifouling performance for clinical diagnostics.
Keywords
Identifiers
- PubMed
- 41527244
- Journal
- Analytical chemistry
- Year
- 2026