Failure Analysis of Li-Cu Reference Electrode in NCM811||Gr Pouch Battery
Jiaxing Hu, Weiling Luan, Huichao Chen, Yuehua Chen
AI summary
75% confidenceThe paper analyzes the failure of a Li-Cu reference electrode in a lithium-ion battery, highlighting its limited lifespan during long-term cycling. The study uses a self-fabricated three-electrode single-layer pouch cell to characterize microstructural changes before and after failure. The findings provide insight into the failure evolution process of the Li-Cu reference electrode.
Generated by MESSAI extraction pipeline · review against source PDF
No 3D model is mapped to this paper yet. Parameter ranges above still place reported values on the literature distribution.
Abstract
div class="section abstract" div class="htmlview paragraph" Reliable monitoring of the internal state of lithium-ion batteries (LIBs) is crucial for mitigating potential safety hazards. The incorporation of a reference electrode (RE) within the battery constitutes a vital approach for achieving single-electrode monitoring and understanding changes in electrode state during cycling. Among these, the lithium-copper reference electrode (Li-Cu RE) is particularly cost-effective and straightforward to prepare, being fabricated by depositing lithium onto a copper wire. However, Li-Cu RE exhibits a relatively short effective lifespan during long-term cycling, thereby limiting its practical application. In this work, based on a self-fabricated three-electrode single-layer pouch cell, the microstructural changes before and after failure of the Li-Cu RE were characterized and analyzed, revealing its failure evolution process. Post-failure microstructures observations exhibit marked porosity in the electrode, attributed to substantial depletion of surface lithium metal. Concurrently, the copper wire's elevated potential dominantly influences the overall Li-Cu RE potential, causing its potential to rise and destabilize. This induces a sharp decline in the measured electrode's potential curve. Furthermore, comparative analysis of key factors influencing Li-Cu RE lifespan were investigated. In the static state, the theoretical failure time of Li-Cu RE differed by only approximately 9 hours from that in the cycling state. Crucially, isolating the test electrode from the Li-Cu RE nearly doubled its lifespan, revealing that current generated by the potential difference between the test electrode and Li-Cu RE is the primary cause of failure under low-rate cycling. This paper systematically elucidates the observed failure behavior of the Li-Cu RE and comprehensively analyzes the various factors, which aids in further understanding the failure mechanism of the Li-Cu RE and identifying targeted solutions. /div /div
Key findings
- Microstructural changes occur in the Li-Cu reference electrode during long-term cycling
- The Li-Cu reference electrode exhibits a relatively short effective lifespan
- Post-failure microstructures observations reveal the failure evolution process
Keywords
Identifiers
- Journal
- SAE Technical Paper Series
- Year
- 2026