This paper introduces an in situ methodology to simultaneously measure oxygen surface exchange coefficients and oxygen vacancy concentrations in mixed ionic–electronic conducting perovskite electrodes under realistic solid oxide cell operating conditions. By applying an overpotential to induce a drop in the oxygen chemical potential gradient, the study directly analyzes defect chemistry and surface reaction kinetics without separating these coupled behaviors. The extracted values validate against established methods while capturing dynamic evolutions in defect chemistry that conventional techniques miss.

Generated by MESSAI extraction pipeline · review against source PDF

Extraction

Reported parameters

No values extracted from this paper yet.

No 3D model is mapped to this paper yet. Parameter ranges above still place reported values on the literature distribution.

Abstract

ABSTRACT Solid oxide electrochemical cells (SOCs) employ mixed ionic–electronic conducting (MIEC) perovskite electrodes, where electrochemical performance is dictated by the oxygen surface exchange coefficient ( k ) and the concentration of oxygen vacancies (δ). Conventional methods evaluate k and δ separately and under conditions that do not reflect their coupled behavior during operation, offering only a partial picture of the underlying processes. Here we report an in situ methodology that simultaneously resolves k and δ under realistic SOC operating conditions, using a dense bulk electrode integrated with a solid electrolyte. An applied overpotential induces an abrupt drop in the oxygen chemical potential gradient, enabling direct analysis of defect chemistry and surface reaction kinetics. The extracted values are consistent with those obtained from established characterization methods, validating the accuracy of the approach. Beyond fundamental characterization, the platform captures dynamic evolutions in defect chemistry and reaction kinetics, providing mechanistic insights into electrode degradation.

Key findings

  • Conventional methods fail to capture the coupled behavior of oxygen surface exchange coefficients and vacancy concentrations during actual cell operation.
  • An applied overpotential creates an abrupt drop in the oxygen chemical potential gradient, enabling direct analysis of defect dynamics.
  • The new platform successfully captures dynamic evolutions in defect chemistry under realistic operating conditions.

Keywords

OverpotentialElectrochemistryOxideElectrodeOxygenIn situ